Page 36
VDC1604 VISTA DOME CONTROLLER
Installation and Operating Instructions
DEFINING AN ALARM RESPONSE
8. Select the
Sounder
field and choose
Short
from the picklist.
9. Select the
No.
field for monitor 1 and enter 00 using the number keys. This
is to ensure that monitor 1 functions as a control monitor.
10. Select the
Cam/View
field for monitor 2 and choose
CAM
from the picklist.
11. Select the
No.
field for monitor 2 and enter 02 using the number keys.
12. Select the
Cam/View
field for monitor 3 and choose
View
from the picklist.
13. Select the
No.
field for monitor 3 and enter 13 using the number keys.
14. Select
Previous menu
to return to the
Alarm handling
menu.
Defining the Alarm output state
1. Select
Output settingss
from the
Alarm handling
menu.
2. Use the joystick to select
NO
from the
Alarm out 1
picklist.
3. Select
Previous menu
to return to the
Alarm handling
menu.
4. Exit the menu system saving your changes.
ALARMS
If a monitor is defined as being included in the alarm response, the alarm process takes precedence over all system
users/operators including users/operators within any of the menu screens (except the alarm definition menu and the
system menu).
While changes are in progress within the alarm definition menu and the system menu, the detection
of alarms will be suppressed
.
The alarm response definition menu allows video selection to monitors 1, 2 and 3. Monitor 4 is used as the primary
display for all current alarms in sequence (except any alarm being displayed on another monitor).
For example, consider three alarms triggered in sequence, called (in this example) A, B and C. The alarm definition for
each alarm determines that they will be shown on monitors 1 and 2. Therefore, monitor 4 (the primary alarm display
monitor) will sequence between alarms B and C while alarm A is displayed on monitors 1 and 2.
After any keyboard has acknowledged alarm A, the displays for alarm A will disappear and the next alarm in precedence,
alarm B, will appear on monitors 1 and 2. Alarm C will appear on monitor 4.
Output settings
Alarm out 1
4
NO
Previous menu
Alarm response
Response
4
AL 1
Priority
H
Active time win
1 2 0 0
Name:
Main entrance
Alarm o/p
On
Sounder
Short
Monitor
Cam/View
No.
1
CAM
00
2
CAM
02
3
VIEW
13
Previous menu