D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
75
The following table presents the test result messages
Message
Description
Unit is OK
GSM / GPRS is functioning correctly
GSM comm. loss
The GSM/GPRS module does not communicate with the Panel
Pin code fail
Missing or wrong PIN code. (Only if SIM card PIN code is enabled.)
GSM net. fail
Unit failed with registration to local GSM network.
SIM card fail
SIM not installed or SIM card failure.
GSM not detected
GSM auto enroll failed to detect GSM/GPRS module.
No GPRS service
The SIM card does not have the GPRS service enabled.
GPRS conn. fail
Local GPRS network is not available or, wrong setting to GPRS APN, user and/or
password.
Srvr unavailable
IPMP Receiver cannot be reached – Check the Server IP
IP not defined
Server IP #1 and #2 are not configured.
APN not defined
APN is not configured.
SIM card locked
After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it
enter a PUK number. The PUK number cannot be entered by the control panel.
Denied by server
The IPMP denies the connection request. Check that the Panel is registered to the
IPMP
3.10 User Settings
This USER SETTINGS menu provides you with a gateway to the user settings through the regular user
programming menu.
Refer to the User's Guide for detailed procedures.
Caution! If after having programmed the user codes the system does not recognize your installer code,
this indicates you must have programmed a user code that is identical with your installer code. If so,
access the user menu and change the code that is identical with your installer code. This will re-validate
your installer code
3.11 Factory Default
3.11.1 General Guidance – "Factory Default" Menu
The FACTORY DEFLT menu enables you to reset the PowerMaster-10 / PowerMaster-30 parameters to the
factory default parameters. To obtain the relevant parameters defaults, contact the PowerMaster-10 /
PowerMaster-30 dealer.
3.11.2 Resetting Factory Default Parameters
To
reset factory default parameters
proceed as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
Select "09:FACTORY
DEFLT" menu
[1]
Select "<OK> to
restore"
[2]
Enter Installer Code
[3]
Resetting of factory
default parameters is
underway
[4]
To
Step 1
09:FACTORY DEFLT
ENTER CODE:
PLEASE WAIT…