No.
VS-AXESS-1ETL
A6
BUTTON
Door Button Input
A7
GND
Grounding
A8
SENSOR
Door Magnetic detector
B1
Alarm Output
COM
Alarm Relay Output (Dry Contact)
B2
NO/NC
B3
Alarm Input
GND
Grounding
B4
IN
Event Input
B5
Wiegand Card
Reader 1
OK
Indicator of Card Reader Control Output
(Valid Card Output)
B6
ERR
Indicator of Card Reader Control Output
(Invalid Card Output)
B7
BZ
Card Reader Buzzer Control Output
B8
W1
Wiegand Head Read Data Input Data1
B9
W0
Wiegand Head Read Data Input Data0
B10
PWR
Card Reader Power Output
B11
GND
B12
Wiegand Card
Reader 2
OK
Indicator of Card Reader Control Output
(Valid Card Output)
B13
ERR
Indicator of Card Reader Control Output
(Invalid Card Output)
B14
BZ
Card Reader Buzzer Control Output
B15
W1
Wiegand Head Read Data Input Data1
B16
W0
Wiegand Head Read Data Input Data0
B17
PWR
Card Reader Power Output
B18
GND
Notes:
The Alarm input hardware interface is normally open by default. So only the normally open signal
is allowed. It can be linked to the buzzer of the card reader and access controller, and the alarm
relay output and open door relat output.
For single-door access controller, the Wiegand card reader 1 and 2 respectively correspond to the
entering and exiting card readers of door 1.
Summary of Contents for VS-AXESS-1ETL
Page 15: ...Access Control Terminal User Manual 7 3 3 Connecting the External Alarm Device...
Page 17: ...Access Control Terminal User Manual 9 3 6 Connecting Power Supply...
Page 20: ...Access Control Terminal User Manual 12...
Page 40: ...Access Control Terminal User Manual 32 8 3 Connecting the External Alarm Device...
Page 42: ...Access Control Terminal User Manual 34 8 6 Connecting Power Supply...