Access Control Terminal
·
User Manual
105
Event Linkage
For the event linkage, the alarm event can be divided into four types: device event, alarm input, door
event, and card reader event.
Steps:
1.
Click to select the linkage type as
Event Linkage
, select the access control device as event source,
and select the event type from the dropdown list.
For Device Event, select the detailed event type from the dropdown list.
For Alarm Input, select the type as alarm or alarm recovery and select the alarm input name
from the table.
For Door Event, select the detailed event type and select the door from the table.
For Card Reader Event, select the detailed event type and select the card reader from the
table.
2.
Set the linkage target, select the access control device from the dropdown list as the linkage
target, and switch the property from
to
to enable this function.
Host Buzzer:
The audible warning of controller will be enabled/disabled.
Capture:
The real-time capture will be enabled.
Card Reader Buzzer:
The audible warning of card reader will be enabled/disabled.
Alarm Output:
The alarm output will be enabled/disabled for notification.
Zone:
Arm or disarm the zone.
Access Control Point:
The door status of open, close, remain open, and remain closed will be
enabled.
Notes:
The door status of open, close, remain open, and remain close cannot be triggered at
the same time.
The target door and the source door cannot be the same one.
3.
Click
Save
button to save parameters.
Card Linkage
Steps:
1.
Click to select the linkage type as
Card Linkage
.
2.
Select the card from the dropdown list and select the access control device as event source.
3.
Select the card reader from the table for triggering.
4.
Set the linkage target, select the access control device from the dropdown list as the linkage
target, and switch the property from
to
to enable this function.
Host Buzzer:
The audible warning of controller will be enabled/disabled.
Capture:
The real-time capture will be enabled.
Card Reader Buzzer:
The audible warning of card reader will be enabled/disabled.
Alarm Output:
The alarm output will be enabled/disabled for notification.
Zone:
Arm or disarm the zone.
Summary of Contents for VS-AXESS-1ETL
Page 15: ...Access Control Terminal User Manual 7 3 3 Connecting the External Alarm Device...
Page 17: ...Access Control Terminal User Manual 9 3 6 Connecting Power Supply...
Page 20: ...Access Control Terminal User Manual 12...
Page 40: ...Access Control Terminal User Manual 32 8 3 Connecting the External Alarm Device...
Page 42: ...Access Control Terminal User Manual 34 8 6 Connecting Power Supply...