5
SL24.T
EN
Controllable actuators
Ref.
Description
ESM2
ACTO 600D 24 V 600 kg sliding gate actuator w/ Dip & Trimmer control panel
Trimmer function
Trimmer Description
FM1
Power of motor (adjusts the torque of motor, turn the trimmer clockwise to increase the force)
VS
Slow-down speed (adjusts the slow-down speed of the motor, turn the trimmer clockwise to increase the speed)
V
Standard speed (adjusts the standard speed of the motor, turn the trimmer clockwise to increase the speed)
TCA
Automatic re-closing time (adjustable from 2 to 120 seconds, turn the trimmer clockwise to increase the time)
Button functions
Button
Description
PROG
Button for programming the travel
MRX
Button for programming or deleting remote controls
51
Step-by-step command button
DIP-switch functions
Dip
Function
Status Description
DIP 1
Automatic closing
OFF
Automatic closing off
ON
Automatic closing on
DIP 2
Apartment block
OFF
Apartment block off
ON
Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with inputs
51 (step-by-step) and 52 (pedestrian). With automatic closing on (DIP 1 = ON) and the gate open, an additional
step-by-step command (terminal 51 or radio command) renews the pause time, and if input 51 remains engaged,
the control panel suspends the pause count until the input is disengaged (for connecting any coils or a timer)
DIP 3
Pre-flash
OFF
Pre-flashing off
ON
Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
DIP 4
Input 63 type
OFF
Input 63 is for internal photocell
ON
Input 63 is for safety edge (see DIP 7 for the safety edge type)
DIP 5
Photo test
OFF
Photo-test function off
ON
Photo-test on: the negative accessory power supply terminal (0) turns off for a few fractions of a second before the
start of movement, so any accessories that require a permanent power supply (e.g. photocell receivers) must get
the negative power supply from an input common (terminal 99).
DIP 6
Output 12
OFF
Output 12 for Courtesy Light (LCO): each time the gate moves, the output remains on for 100 s.
The remote control buttons saved on the second radio channel give a pedestrian command
ON
Output 12 for Auxiliary Radio output: the remote control buttons saved on the second radio channel turn the output
on for 1 s
DIP 7
Safety edge type
OFF
Sensitive edge with normally closed contact
ON
Resistive sensitive edge, normally open contact with balancing resistance of 8.2 K Ohm in parallel
DIP 8
Rapid closing
OFF
Fast closing off
ON
Fast closing function on: if the closing photocell (terminal 62) is engaged, the automatic closing time is set to 5
seconds when it is released
DIP 9
Not used
DIP 10
Opening
direction
OFF
Gate opening to the left
ON
Gate opening to the right
LED functions
LED
Status
Description
PWR
OFF
Mains power supply not present
ON
Mains power supply present
PRG
(or flashing light)
2 blinks
Photocell test failed (incorrect wiring or photocells busy)
3 blinks
Problem detected in the circuit that activates motor
4 blinks
Problem on encoder (encoder damaged or wired incorrectly)
5 blinks
Serious EEPROM error (EEPROM missing or damaged)
6 blinks
Motor timeout (gear motor not engaged or damaged)
7 blinks
Fuse F2 blown
8 blinks
Motor overcurrent error
9 blinks
Inverted motor power supply cables (terminals 21-22)
ENCA
OFF
When the motor is operating: first encoder channel signal absent (encoder not working)
ON
When the motor is operating: first encoder channel present (it flashes very fast, depending on the motor rotation
speed)