Instructions for use and maintenance of pressure vessels
Pressure vessels models
Type
Description
OD236
OD278
OD298
OD350
OD395
OD457
OD508
Construction for pressure P
8.8 bar/ 880kpa
Maximum allowed pressure
PS
8.0 bar/ 800kpa
Operating temperature
Tmin ~ Tmax
-10
℃
~
+100
℃
The volume of vessel V (L)
21
~
36L
40
~
60L
50
~
80L
70
~
100L
100
~
200L
115
~
250L
250
~
370L
Allowed corrosion c
0.5 mm
Wall thickness
2.0mm
2.0mm
2.0mm
2.5mm
3.0mm
3.0mm
3.5mm
Considered standards and
directives
SPV 2014/29/EU & EN286-1:1998+A1:2002+A2:2006
1.
The operating pressure must not exceed the maximum permissible pressure. The user is
responsible for the problems arising from the exceeding of the maximum allowed pressure.
2.
Pressure vessel is used for oil-lubricated compressors.
3.
The pressure vessel is an important part of the air compressor. The air compressor can’t
function - until all necessary components are plugged in, especially the safety components.
The safety valve must be tested before the compressor can function normally.
4.
Pressurized container must have at least one safety valve. Prior to installation, the safety
valve must be checked by an authorized organization. During the lifetime of the pressure
vessel, the safety valve must be inspected at least once a year to prevent corrosion.
Compressor runs
continuously and air
output is lower than
normal/low discharge
pressure
1.
Excessive air usage,
compressor too small
2.
Clogged intake filter
3.
Air leaks in piping (on
machine or in outside
system)
4.
Broken inlet valves
5.
Piston ring worn
1.
Decrease usage or purchase unit with
higher air delivery (SCFM)
2.
Clean or replace
3.
Replace leaking components or tighten as
necessary
4.
Replace compressor valves
5.
Replace piston and cylinder
Excessive moisture in
discharge air
1.
Excessive water in tank
2.
High humidity
1.
Drain tank
2.
Move to area of less humidity; use air line
filter
NOTE: Water condensation is not caused by
compressor malfunction
Compressor runs
continuously and safety
valve opens as pressure
rises
1.
Defective pressure switch
2.
Defective safety valve
1.
Replace switch
2.
Replace safety valve with genuine
replacement part
Excessive starting and
stopping (auto start)
Excessive condensation in
tank
Drain more often
Air leaking from
unloader on pressure
switch
Check valve stuck in an open
position
Remove and replace check valve
DANGER! Do not disassemble check valve with
air in tank; bleed tank
Summary of Contents for SILENT FORCE VAT 264/50
Page 1: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 ORIGINALNA NAVODILA ZA UPORABO ...
Page 18: ...AIR COMPRESSOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 ORIGINAL OPERATION MANUAL ...
Page 35: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Originalno uputstvo za upotrebu ...
Page 51: ...КОМПРЕСОР SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Оригинални инструкции за употреба ...
Page 69: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Izvorne upute za uporabu ...
Page 86: ...КОМПРЕСОР SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Оригинални упатства за употреба ...
Page 104: ...COMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Manual original de utilizare ...
Page 121: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Pôvodný návod na použite ...
Page 138: ......