INSTALLATION
LOCATION
It is extremely important to install the compressor in a clean, well ventilated area where the
surrounding air temperature will not be more than 38°C.
A minimum clearance of 46 cm between the compressor and a wall is required because objects
could obstruct airflow.
Do not locate the compressor air inlet near steam, paint spray, sandblast
areas or any other source of contamination. This debris will damage the
motor.
ELECTRICAL INSTALLATION
All wiring and electrical connections should be performed by a qualified
electrician. Installation must be in accordance with local codes and national
electrical codes.
1. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be
rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical
codes for this minimum.
2. Use a slow blow fuse or a circuit breaker.
OPERATION
Pressure Switch - Auto/Off Switch-In the AUTO position, the compressor shuts off automatically
when tank pressure reaches the maximum preset pressure. In the OFF position, the compressor will
not operate. This switch should be in the OFF position when connecting or disconnecting the power
cord from the electrical outlet or when changing air tools.
Regulator - The regulator controls the amount of air pressure released at the hose outlet.
Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum.
Discharge Tube - This tube carries compressed air from the pump to the check valve. This tube
becomes very hot during use. To avoid the risk of severe burns, never touch the discharge tube.
Check Valve - A one-way valve that allows air to enter the tank, but prevents air in the tank from
flowing back into the compressor pump.
Handle - Designed to move the compressor.
Never use the handle on wheeled units to lift the unit completely off the
ground.
Drain Petcock - This valve is located on the bottom of the tank. Use this valve to drain moisture from
the tank daily to reduce the risk of corrosion.
Reduce tank pressure below 10 psi (0,69bar), and then drain moisture from tank daily to avoid tank
corrosion. Drain moisture from tank by opening the drain petcock located underneath the tank.
Summary of Contents for SILENT FORCE VAT 264/50
Page 1: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 ORIGINALNA NAVODILA ZA UPORABO ...
Page 18: ...AIR COMPRESSOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 ORIGINAL OPERATION MANUAL ...
Page 35: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Originalno uputstvo za upotrebu ...
Page 51: ...КОМПРЕСОР SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Оригинални инструкции за употреба ...
Page 69: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Izvorne upute za uporabu ...
Page 86: ...КОМПРЕСОР SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Оригинални упатства за употреба ...
Page 104: ...COMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Manual original de utilizare ...
Page 121: ...KOMPRESOR SILENT FORCE VAT 264 50 SILENT FORCE VAT 528 50 Pôvodný návod na použite ...
Page 138: ......