
3
Villager
JGP 1100 F (GB)
15. Please don't bend, extrude, pull or drive the power wire to avoid the related
dangers caused by line breakage.
16 Please check the plug and power cable before application. When the power
cable has been damaged, please disconnect the plug immediately. Please don't use
the equipment which has damaged power line.
17. When the equipment is idle, please ensure that the plug has been pulled out.
Meanwhile, the equipment has been closed, then, unplug the power supply.
As for the fixed application, please apply four screws to tighten the equipment
on the foundation support firmly.
When the equipment is used for the pound and swimming pool in the garden,
the equipment shall be subject to the special setup to avoid the overflow and
falling.
The equipment shall be installed in the well-ventilated places to avoid the
weather effect. In case of indoor operation, please ensure that the floor is
equipped with drainage ditch or leakage-proof mechanism.
Please check the suction hose and guarantee its airtightness before startup.
When the air foam is absorbed in the hose, the equipment is likely to be out of
order because the leakage exists possibly.
All interfaces which are connected to the suction pipeline shall be sealed by
hemp and thick slurry or sealing tape. The leakage will reduce the air exhaust.
The interface of metal pipe thread shall be sealed by sealing tape.
All components of suction pipeline shall be installed by professionals.
The inner diameter of suction pipe shall be 25mm at least; The suction pipe
shall be kinking resistant and suitable for the vacuum environment.
Considering that the increasing pipe length will reduce the transmission
capacity, the suction pipeline shall be as short as possible.
The suction pipeline shall uplift the pump steadily to avoid any bubbles.
Danger type and source!
In order to avoid any mechanical force or tension, the suction pipeline
shall be installed.
When the transmission pipeline is polluted, please apply filter to
make cleaning and
protection.
Danger!
Attention:
We advise to install one check value to avoid the equipment
shutdown which is caused by water loss absence during the pump.
Summary of Contents for JGP 1100 F
Page 1: ...1 Villager JGP 1100 F SI VRTNA RPALKA Villager JGP 1100 F ORIGINALNA NAVODILA ZA UPORABO...
Page 10: ...1 Villager JGP 1100 F GB GARDEN PUMP Villager JGP 1100 F ORIGINAL INSTRUCTIONS...
Page 19: ...1 Villager JGP 1100 F RS PUMPA ZA BA TU Villager JGP 1100 F ORIGINALNO UPUTSTVO ZA UPOTREBU...
Page 27: ...9 Villager JGP 1100 F RS...
Page 28: ...10 Villager JGP 1100 F RS...
Page 30: ...1 Villager JGP 1100 F BG Villager JGP 1100 F...
Page 31: ...2 Villager JGP 1100 F BG 1 2 3 4 5 6 7 8 9 10 11 12...
Page 32: ...3 Villager JGP 1100 F BG 13 30 mA 14 15 16 17...
Page 33: ...4 Villager JGP 1100 F BG 25 mm...
Page 34: ...5 Villager JGP 1100 F BG 1 2 3 30 mA 4 5 1 2 3 4 5 6 7 8 1 2...
Page 35: ...6 Villager JGP 1100 F BG 3 1 1 2 2 3 3...
Page 36: ...7 Villager JGP 1100 F BG 4 4 5 5 1 1 2 2 3 3 1 1 2 2 3 3...
Page 37: ...8 Villager JGP 1100 F BG 230V 50Hz 1100 W IPX4 45 m 8m 4600 l h 4 5 bar 4 4 5 5 6 o 6...
Page 39: ...1 Villager JGP 1100 F GR Villager JGP 1100 F...
Page 40: ...2 Villager JGP 1100 F GR 1 2 3 4 5 6 7 8 9 10...
Page 41: ...3 Villager JGP 1100 F GR 11 12 13 30 mA 14 O 15 16 17 O H...
Page 42: ...4 Villager JGP 1100 F GR 25 mm H vacuum...
Page 43: ...5 Villager JGP 1100 F GR 1 2 3 30 mA 4 5 1 2 3 4 O...
Page 44: ...6 Villager JGP 1100 F GR 5 6 7 8 1 2 3...
Page 45: ...7 Villager JGP 1100 F GR 1 1 2 2 3 3 4 4 5 5...
Page 46: ...8 Villager JGP 1100 F GR 1 1 2 2 3 3 1 1 2 2 3 3 4 4 5 5 6 6...
Page 47: ...9 Villager JGP 1100 F GR 230V 50Hz 1100 W IPX4 45 m 8m 4600 l h 4 5 bar...
Page 49: ...1 Villager JGP 1100 F HR CRPKA ZA BA U Villager JGP 1100 F ORIGINALNE UPUTE ZA UPORABU...
Page 58: ...1 Villager JGP 1100 F HU KERTI SZIVATTY Villager JGP 1100 F EREDETI HASZN LATI UTAS T S...
Page 67: ...1 Villager JGP 1100 F MK Villager JGP 1100 F O O...
Page 68: ...2 Villager JGP 1100 F MK O 1 2 3 O 4 5 6 O 7 8 9 10 T O...
Page 69: ...3 Villager JGP 1100 F MK 11 12 O 13 30 mA 14 15 16 17 O O...
Page 70: ...4 Villager JGP 1100 F MK 25 mm O...
Page 71: ...5 Villager JGP 1100 F MK O 1 O 2 3 O 30mA 4 5 1 O 2 3 a a O O a O O O...
Page 72: ...6 Villager JGP 1100 F MK 4 5 6 7 8 O E 1 2 3 O...
Page 73: ...7 Villager JGP 1100 F MK 1 1 2 2 3 3 4 Mo 4 5 5 O...
Page 74: ...8 Villager JGP 1100 F MK 1 Mo 1 2 Mo 2 3 Mo 3 1 1 2 Mo 2 3 Mo 3 4 Mo 4 5 Mo 5 6 Mo 6...
Page 75: ...9 Villager JGP 1100 F MK TE 230V 50Hz 1100 W IPX4 45 m 8m M 4600 l h 4 5 bar O o O...
Page 86: ...1 Villager JGP 1100 F SK Z HRADN ERPADLO Villager JGP 1100 F ORIGIN LNY N VOD NA POU ITIE...
Page 95: ......