Viking K-1900-7-EWP Product Manual Download Page 5

5

Installation and Mounting

Side View

of the K-1900-7-IP

(8) #6-32 x 3/4" Stainless Steel T-10 

Torx Security Screws (included)

Optional VE-5x10 Surface 

Mount Box (not included)

- OR -

10.0"

9.5"

4.50"

5.00"

3.28"

1.55"

Front View

of the K-1900-7-IP

1.8"

2.75"

2.1"

3.5"

Double Gang Box

(not included)

2.69”

10.14”

5.22”

3.69”

4.50”

9.50”

2.75"

2.1"

3.5"

Double Gang Box

(not included)

Side View of

the K-1900-6-IP

(4) #6-32 x 3/4" Stainless Steel, 

Flat Head T-10 Torx Security

Screws and Drive Bit (included)

4.5"

1.8"

4.56"

3.28"

Front View

of the K-1900-6-IP

To install the 

K-1900-6-IP 

panel phone, attach the panel to a standard double gang electrical box using the provided screws.

Tip

: Record the MAC address that is printed on the network jack. This number will be used later in programming. 

A.  Installing the K-1900-6-IP

B.  Installing the K-1900-7   -IP

To install the 

K-1900-7-IP 

panel phone, attach the panel to a standard double gang electrical box using the provided

screws or use the optional 

VE-5x10

or 

VE-5X10-SS

weather resistant surface mount box.  

Note:

Four extra screws

and nuts are provided to fill the unused mounting holes. 

The optional 

VE-5x10

surface mount box (shown below) is

designed to be surface mounted to a wall, post, single gang box or a 

VE-GNP

or 

VE-GNP-2

goose neck pedestal. The

K-1900-7-IP

can also be mounted in an optional 

VE-9x20

Weatherproof Enclosure (

DOD 413

). 

Note:

When mounting a 

K-1900-7-IP-EWP

in a 

VE-9x20

, the length of the handset cable must be reduced. Use a

3/32” hex key or bit to loosen the set screw in the brass handset cable retainer. Pull approximately 18 inches of the
cable through the panel and retighten the set screw.

Tip: Record the MAC address that is printed on the network jack. This number will be used later in programming.

Summary of Contents for K-1900-7-EWP

Page 1: ...del Phone only 5 0 x 10 0 x 5 1 127mm x 254mm x 130mm Including rough in box 5 0 x 10 0 x 5 4 127mm x 254mm x 137mm Shipping Weight for K 1900 6 IP 2 0 lbs 0 9 kg Shipping Weight for K 1900 7 IP 3 7 l...

Page 2: ...tform V6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstre...

Page 3: ...nsport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A co...

Page 4: ...designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Front View of the K 1900 7 IP VoIP Panel Phone Condensation Drain Hole Mounting Screws 8 6 32 x 3 4...

Page 5: ...g the K 1900 6 IP B Installing the K 1900 7 IP To install the K 1900 7 IP panel phone attach the panel to a standard double gang electrical box using the provided screws or use the optional VE 5x10 or...

Page 6: ...IP Entry Phone 4 K 1900 6 IP Entry Phone 3 N O COM 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 2 N O COM Relay 4 Output Contacts 5A 30VDC 250VAC max C...

Page 7: ...oIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking K 1900 6 7 IP VoIP Phone Note A PoE exten...

Page 8: ...ame MAC addresses must be used to identify each phone When finished programming click on the Disconnect button at the bottom Closing the program will also automatically disconnect the unit With the un...

Page 9: ...it Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below E Manually Resetting All Network Parameters to Fac...

Page 10: ...Mode Ring Ring Flash factory set to Door Strike 14 13 Relay Activation Command 1 or 2 digits factory set to QQ Relay Mode must be set to Door Strike 15 13 Relay Activation Time 0 5 99 sec factory set...

Page 11: ...her way to update is accomplished by clicking the IP firmware Update button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically on...

Page 12: ...ing pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of t...

Page 13: ...ory setting is 5 seconds THis also controls the length of relay closure in Door Bell Mode 16 Relay Activation Time Doorstrike Mode When programmed for Doorstrike Mode the relay is intended for door st...

Page 14: ...you are making an outbound call through your VoIP phone system and are relying on In Band analog audio for ringback or busy detection The factory default is Enabled 19 In Band Audio Call Progress The...

Page 15: ...nd you can now enter the Remote Access Operation Commands below The relay must be set to Door Strike Mode to be controlled by these commands Note Latching commands must be enabled in programming Troub...

Page 16: ...m panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with...

Page 17: ...r SIP VoIP phone systems with PoE The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address The K 1900 8 IP phone can dial up to 250 programmable numbers and another...

Page 18: ...to a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has...

Reviews: