Viking K-1900-7-EWP Product Manual Download Page 16

16

Related Products

The 

VE-LIGHT

kit adds bright LED illumination to any VoIP entry phone that is

housed in a Viking 

VE-5x5

VE-6x7

or 

VE-5x10

enclosure. 

The stainless steel bracket is easily mounted using existing holes and hardware.
Two bright white LEDs are used as the light source, so there are no filaments to
break or bulbs to burn out. 

12 VDC power adapter included. Any power source between 12 and 24 volts, AC or
DC can be used to supply the 

VE-LIGHT

with power.

For more information, See 

DOD 428

Add Panel Lighting to Your Viking VoIP Entry Phone

VE-LIGHT shown right with Viking

E-30    and VE-5x5 (not included)

VE-GNP-SS

VE-GNP

VE-GNP-2

VE-GNP-IG

VE-GNP-SS

VE-GNP

Surface or Pedestal Mount Viking Products

While Maintaining Weather and Vandal Resistance

VE-5x5

VE-5x5-SS

VE-5x5-RD

VE-5x5-PNL VE-5x5-PNL-SS

VE-6x7

VE-6x7-SS

VE-6x7-PNL

VE-6x7-PNL-SS

VE-5x10

VE-5x10-SS VE-5x10-PNL VE-5x10-PNL-SS

VE-3x5*

VE-5x10-NR VE-5x10-NR-SS

The 

VE-PNL

’s are 

VE-Series 

backboxes with a blank aluminum panel. The user can

customize the clear-coated aluminum panel to mount an 

PRX-1

card reader, 

PRX-

keypad or switch.  The kits come complete with box, gasket, panel and screws.

Model numbers that end with “SS” are stainless steel version.    

Note: 

The use of

magnets to mount the 

VE-Series

enclosure to a metal surface can affect the

operation of the enclosed product.

Caution: 

Handsfree phones are not suitable for noisy applications (see “Important”

on page 2).

For more information on Viking Surface Mount Boxes and Pedestals, see

DOD 424

.

The 

VE-3x5

VE-5x5

VE-6x7

and 

VE-5x10

add vandal and

weather resistance, as well as versatility to many Viking products.
The 

VE-Series

backboxes are available in black fine texture

powder painted steel or marine grade 316 stainless steel. The
weather resistant boxes are designed to be surface mounted to
a wall, post, single gang box, or a 

VE-GNP

gooseneck pedestal.

Note:

The 

VE-3x5

is not compatible with the 

VE-GNP 

pedestals

and is not available in stainless steel.

The 

VE-GNP

gooseneck pedestals

are designed to be used with the

VE-5x5

VE-6x7

and 

VE-5x10

backboxes and are ideal for drive
up communications. 

Note:

The

VE-3x5

is not compatible with the

VE-GNP 

pedestals.

Summary of Contents for K-1900-7-EWP

Page 1: ...del Phone only 5 0 x 10 0 x 5 1 127mm x 254mm x 130mm Including rough in box 5 0 x 10 0 x 5 4 127mm x 254mm x 137mm Shipping Weight for K 1900 6 IP 2 0 lbs 0 9 kg Shipping Weight for K 1900 7 IP 3 7 l...

Page 2: ...tform V6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstre...

Page 3: ...nsport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A co...

Page 4: ...designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Front View of the K 1900 7 IP VoIP Panel Phone Condensation Drain Hole Mounting Screws 8 6 32 x 3 4...

Page 5: ...g the K 1900 6 IP B Installing the K 1900 7 IP To install the K 1900 7 IP panel phone attach the panel to a standard double gang electrical box using the provided screws or use the optional VE 5x10 or...

Page 6: ...IP Entry Phone 4 K 1900 6 IP Entry Phone 3 N O COM 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 2 N O COM Relay 4 Output Contacts 5A 30VDC 250VAC max C...

Page 7: ...oIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking K 1900 6 7 IP VoIP Phone Note A PoE exten...

Page 8: ...ame MAC addresses must be used to identify each phone When finished programming click on the Disconnect button at the bottom Closing the program will also automatically disconnect the unit With the un...

Page 9: ...it Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below E Manually Resetting All Network Parameters to Fac...

Page 10: ...Mode Ring Ring Flash factory set to Door Strike 14 13 Relay Activation Command 1 or 2 digits factory set to QQ Relay Mode must be set to Door Strike 15 13 Relay Activation Time 0 5 99 sec factory set...

Page 11: ...her way to update is accomplished by clicking the IP firmware Update button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically on...

Page 12: ...ing pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of t...

Page 13: ...ory setting is 5 seconds THis also controls the length of relay closure in Door Bell Mode 16 Relay Activation Time Doorstrike Mode When programmed for Doorstrike Mode the relay is intended for door st...

Page 14: ...you are making an outbound call through your VoIP phone system and are relying on In Band analog audio for ringback or busy detection The factory default is Enabled 19 In Band Audio Call Progress The...

Page 15: ...nd you can now enter the Remote Access Operation Commands below The relay must be set to Door Strike Mode to be controlled by these commands Note Latching commands must be enabled in programming Troub...

Page 16: ...m panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with...

Page 17: ...r SIP VoIP phone systems with PoE The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address The K 1900 8 IP phone can dial up to 250 programmable numbers and another...

Page 18: ...to a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has...

Reviews: