Viking K-1900-7-EWP Product Manual Download Page 17

17

Control Relay Contacts Across a Local Area Network

The 

RC-4A

Network Enabled Relay Controller provides networked control

of four relays via an easy-to-use web interface.  The same interface can
be used to check the status of four contact closure inputs. Relays can be
toggled on or off, or user-programmed timed closures can be activated.

The 

RC-4A

can be configured to work as a remote relay for Viking VoIP

series entry phones, controlling door strikes and gates when a remote
relay is required for security reasons.  It can also be programmed to send
an email or text message in response to a change in one or more of the
sensor inputs. Two 

RC-4A’s

can be set up so that activity on a sensor

input of one unit will automatically send a message across the network to
activate one of the relays on the other unit. Two levels of user access
permit selected users to have full operational and programming rights
while others have operational control but not programming capability.

Related Products

For more info, see 

DOD 582

For more info, see 

DOD 361

The 

K-1900-8-IP VoIP

panel phone can either auto-dial a phone number each time the handset

is lifted, be used as a multi-number auto-dialer, or be used as a standard manual dial phone.
The 

K-1900-8-IP

VoIP phone is designed to provide quick and reliable communication for SIP

VoIP phone systems with PoE.  The unit can be programmed from any PC on the same LAN
or remotely using a Static IP Address. The 

K-1900-8-IP 

phone can dial up to 250

programmable numbers and another 250 rollover numbers.

When a call initiated by the 

K-1900-8-IP

phone is answered by an apartment or business

tenant, a built-in contact closure may be activated to control an electric gate or door strike. Up
to 1,000 keyless entry codes may be programmed, providing tenants with keyless entry. A 26
Bit Wiegand input is provided for adding an optional proximity card reader with capacity to
program up to 1,000 card numbers. Keyless entry codes and card numbers can be
programmed to only allow access at specific times and/or day of the week. A request for exit
(REX) input is included for easy exiting. The 

K-1900-8-IP

also has automatic event logging

allowing you to review the time and date of the call, which door was open/closed, what keyless
entry code or proximity card was used, request for exit usage and whether it was an inbound
or outbound call.

The 

K-1900-8-IP-EWP

shares all of the features of the 

K-1900-8-IP

in addition to Enhanced

Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation
or condensation.  EWP products feature foam rubber gaskets and boots, sealed connections,
gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards. For more
information on EWP, see

DOD 859

.

Vandal Resistant VoIP Phone 

with Auto Dialer, Keypad and Entry System

Summary of Contents for K-1900-7-EWP

Page 1: ...del Phone only 5 0 x 10 0 x 5 1 127mm x 254mm x 130mm Including rough in box 5 0 x 10 0 x 5 4 127mm x 254mm x 137mm Shipping Weight for K 1900 6 IP 2 0 lbs 0 9 kg Shipping Weight for K 1900 7 IP 3 7 l...

Page 2: ...tform V6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstre...

Page 3: ...nsport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A co...

Page 4: ...designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Front View of the K 1900 7 IP VoIP Panel Phone Condensation Drain Hole Mounting Screws 8 6 32 x 3 4...

Page 5: ...g the K 1900 6 IP B Installing the K 1900 7 IP To install the K 1900 7 IP panel phone attach the panel to a standard double gang electrical box using the provided screws or use the optional VE 5x10 or...

Page 6: ...IP Entry Phone 4 K 1900 6 IP Entry Phone 3 N O COM 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 2 N O COM Relay 4 Output Contacts 5A 30VDC 250VAC max C...

Page 7: ...oIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking K 1900 6 7 IP VoIP Phone Note A PoE exten...

Page 8: ...ame MAC addresses must be used to identify each phone When finished programming click on the Disconnect button at the bottom Closing the program will also automatically disconnect the unit With the un...

Page 9: ...it Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below E Manually Resetting All Network Parameters to Fac...

Page 10: ...Mode Ring Ring Flash factory set to Door Strike 14 13 Relay Activation Command 1 or 2 digits factory set to QQ Relay Mode must be set to Door Strike 15 13 Relay Activation Time 0 5 99 sec factory set...

Page 11: ...her way to update is accomplished by clicking the IP firmware Update button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically on...

Page 12: ...ing pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of t...

Page 13: ...ory setting is 5 seconds THis also controls the length of relay closure in Door Bell Mode 16 Relay Activation Time Doorstrike Mode When programmed for Doorstrike Mode the relay is intended for door st...

Page 14: ...you are making an outbound call through your VoIP phone system and are relying on In Band analog audio for ringback or busy detection The factory default is Enabled 19 In Band Audio Call Progress The...

Page 15: ...nd you can now enter the Remote Access Operation Commands below The relay must be set to Door Strike Mode to be controlled by these commands Note Latching commands must be enabled in programming Troub...

Page 16: ...m panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with...

Page 17: ...r SIP VoIP phone systems with PoE The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address The K 1900 8 IP phone can dial up to 250 programmable numbers and another...

Page 18: ...to a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has...

Reviews: