17. Relay Internal / External

With the relay set to “Internal” the 

K-1900-6/7-IP

will activate its on board relay for door strike / gate control. The relay

should be set to “External” for higher security installations when using a remote Viking model 

RC-4A

relay controller

to activate the door strike / gate controller (see page 6). 

NOTE: The internal relay will follow the action of the external

relay if used.

When programmed to “Enable” (factory default) the Remote Access Operation Commands to Un-Latch, Latch or toggle
the relay are enabled. The relay mode must be set to doorstrike to use the commands.

When programmed to “Disable” the Remote Access Operation Commands to Un-Latch, Latch or toggle the relay are
disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc.

18. Relay Latch Commands (Enable / Disable Relay Latching Commands)

The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate the relay to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain 0 - 9,  # or 

Q

. The code cannot match a relay latching or toggle

command (11, 10, 1#) unless latching commands are disabled. The code must be entered while the remote phone is
communicating with the Entry phone. The Entry phone determines which direction the touch tone is coming from and
only responds to touch tones from the called phone. The factory setting is 

QQ

.

15. Relay Activation Command 

The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary
touch tone command is entered. This number can range from 0.5 to 99 seconds. The factory setting is 5 seconds. THis
also controls the length of relay closure in “Door Bell “ Mode.

16. Relay Activation Time 

Doorstrike Mode:  

When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control.

The relay will momentarily activate for the preprogrammed relay activation time after detecting the correct relay activation
command (one or two digit touch tone) from the called party.

    

Outbound Call Mode: 

When programmed for Outbound Call Mode the relay will activate continuously for the duration of

any outbound call from the Entry phone. 

Inbound/Outbound Call Mode:  

When programmed for Inbound/Outbound Call Mode the relay will activate continuously

for the duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning on IR flood lights,
for VoIP phones with cameras, etc. 

Doorbell Mode:  

When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed

relay activation time on any outbound call from the Entry phone. This mode is useful for activating a door chime, etc. When
activating door chimes, a 0.5 - 1 second relay activation time is recommended.

Alarm Mode:  

When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and

registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which can be used
to signal an alarm device. 

Ring Mode:  

When programmed for  Ring Mode the relay will continuously activate when an inbound call is ringing to the

entry phone. This mode is useful for activating a Viking model 

SL-2

strobe light, etc.

Note:

Inbound Call Mode must be set to Ring Low or Ring High.

Ring Flash Mode:  

When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off

cadence when an inbound call is ringing to the entry phone. This mode is useful for activating a Viking 

LPL-1

Remote Visual

Indicator, etc.

Note:

Inbound Call Mode must be set to Ring Low or Ring High.

14. Relay Mode 

Summary of Contents for K-1900-7-EWP

Page 1: ...del Phone only 5 0 x 10 0 x 5 1 127mm x 254mm x 130mm Including rough in box 5 0 x 10 0 x 5 4 127mm x 254mm x 137mm Shipping Weight for K 1900 6 IP 2 0 lbs 0 9 kg Shipping Weight for K 1900 7 IP 3 7 l...

Page 2: ...tform V6 2 9 or earlier Avaya IP Office Platform BlueBox Brekeke Cisco Unified Communications Manager CUCM Cisco Unified Communications Manager Express CUCME Elastix epygi QX200 4 Freeswitch Grandstre...

Page 3: ...nsport Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A co...

Page 4: ...designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Front View of the K 1900 7 IP VoIP Panel Phone Condensation Drain Hole Mounting Screws 8 6 32 x 3 4...

Page 5: ...g the K 1900 6 IP B Installing the K 1900 7 IP To install the K 1900 7 IP panel phone attach the panel to a standard double gang electrical box using the provided screws or use the optional VE 5x10 or...

Page 6: ...IP Entry Phone 4 K 1900 6 IP Entry Phone 3 N O COM 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Entry Phone 2 N O COM Relay 4 Output Contacts 5A 30VDC 250VAC max C...

Page 7: ...oIP Phone System SIP VoIP PBX or PC with SIP Server Software 100m 328 ft maximum Viking supplies Customer s Responsibility Internet 10 100 Mbps Maximum Viking K 1900 6 7 IP VoIP Phone Note A PoE exten...

Page 8: ...ame MAC addresses must be used to identify each phone When finished programming click on the Disconnect button at the bottom Closing the program will also automatically disconnect the unit With the un...

Page 9: ...it Name field When finished click on the Apply button to send the IP settings to the connected unit See Examples 1 and 2 of the required fields below E Manually Resetting All Network Parameters to Fac...

Page 10: ...Mode Ring Ring Flash factory set to Door Strike 14 13 Relay Activation Command 1 or 2 digits factory set to QQ Relay Mode must be set to Door Strike 15 13 Relay Activation Time 0 5 99 sec factory set...

Page 11: ...her way to update is accomplished by clicking the IP firmware Update button You can then browse to the folder that contains the PIP file for updating the unit s IP firmware This method is typically on...

Page 12: ...ing pattern selected in Ring Cadence The call can then be answered by taking the handset off hook Ring High In the High mode the phone will output a slightly louder higher pitched ring signal out of t...

Page 13: ...ory setting is 5 seconds THis also controls the length of relay closure in Door Bell Mode 16 Relay Activation Time Doorstrike Mode When programmed for Doorstrike Mode the relay is intended for door st...

Page 14: ...you are making an outbound call through your VoIP phone system and are relying on In Band analog audio for ringback or busy detection The factory default is Enabled 19 In Band Audio Call Progress The...

Page 15: ...nd you can now enter the Remote Access Operation Commands below The relay must be set to Door Strike Mode to be controlled by these commands Note Latching commands must be enabled in programming Troub...

Page 16: ...m panel The user can customize the clear coated aluminum panel to mount an PRX 1 card reader PRX 2 keypad or switch The kits come complete with box gasket panel and screws Model numbers that end with...

Page 17: ...r SIP VoIP phone systems with PoE The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address The K 1900 8 IP phone can dial up to 250 programmable numbers and another...

Page 18: ...to a PO Box 4 RA number on carton In large printing write the R A number on the outside of each carton being returned RETURNING PRODUCT FOR EXCHANGE The following procedure is for equipment that has...

Reviews: