background image

4

Wiring

Rear View of the

Phone Panel

Ring Connector
(included)

* Earth Ground

(optional)

** Gel-Filled Butt

Connectors 

(included)

Note: Polarity Sensitive!

*** Drip

Loop

BLK-4 Control 

Module 

(included)

rotated 90°

(-) Black with 

Red stripe

120V AC

(+) Red with
Black stripe

Red (+)

Black (-)

Green (see section F page 6)

Rear View of the SL-2

Strobe Light 

(included)

see Programming page 6

Red with 

Yellow stripe

Green with 

Yellow stripe

Brown

Gray

Auxiliary Relay Contact Output

(see section D on page 5)

Blue

Blue

Incoming

Analog

Phone Line

Phone or

Terminal

Device 

(not included)

Purple

Orange

Yellow

12V DC

Adapter

(included)

White

White

Disable Feature

(see section E on page 6)

Note: 

Not polarity sensitive.

Trigger Input for Optional

Remote Trigger Switch

(see section G on page 6)

Rear View of Legacy 

SL-1 Strobe Light 

(included with 2012 and older 

E-1600A-BLT-EWP 

models)

Black

Red

Negative

Positive

1

3

3

2

ON

ON

* Note:

To increase surge protection, loosen the PCB mounting screw labeled        (as shown) and fasten a wire with ring connector

(included) from the mounting screw to Earth Ground (grounding rod, water pipe, etc.)

IMPORTANT:

Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the

telephone line.  It is recommended that a surge protector be installed to protect against such surges.  

** Note:

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum

insulation of 0.082 inches. Cut off bare wire ends prior to terminating.

*** Note: 

When wires are routed from above, a “drip loop” is recommended to keep water away from the circuit board.

DIP Switch 4 OFF

DIP Switch 4 ON

N.C.

+12VDC Normally ON

COM

+12VDC

N.O.

+12VDC Normally OFF

Summary of Contents for E-1600A-AS T2EWP

Page 1: ...s 9 1 kg Mounting Surface mount to rigid wall or post Operating Temperature 15 F to 130 F 26 C to 54 C Humidity Up to 100 Strobe Flash Rate 60 flashes per minute default see page 7 for more info Maxim...

Page 2: ...O Push to Call Button models E 1600A AST2EWP and E 1600A BLT2EWPonly Solid 316 stainless steel internally sealed per IP67 Grade 2 Braille Label Laser Etched Graphics Mounting Screws 4 T 10 Torx head s...

Page 3: ...th wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above the floor to a flat sturdy surface using 5 16 hardware Note Flat washers should be used on the main mounting bolt...

Page 4: ...r View of Legacy SL 1 Strobe Light included with 2012 and older E 1600A BLT EWP models Black Red Negative Positive 1 3 3 2 ON ON Note To increase surge protection loosen the PCB mounting screw labeled...

Page 5: ...he load to snub high voltage spikes With DIP switch 4 ON wet switched 12VDC 100mA maximum will be output on the yellow wire and GND on the black wire 2 Loop Off hook Indication Only Place DIP switch 1...

Page 6: ...o 6 Brightest After selecting Programming Feature 5 Beacon Brightness wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting Touch and hold the Green Control wire to t...

Page 7: ...ects an incoming ring signal it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light With the Ring Cadence mode off DIP s...

Page 8: ...When the 1600A Series phone answers a double beep should then be heard and will automatically enter the programming mode Step 5 When finished programming move DIP switch 3 back to the ON position see...

Page 9: ...he security office can display the number using a Touch Tone decoder To program the I D number enter the desired number followed by 20 Example To store 333 as the I D number enter 3 3 3 2 0 2 INFO Spe...

Page 10: ...ignal busy signal silence or return to dial tone to hang up Use chart at the right Note The factory default is 3 minutes Setting C Silence Time Out This feature selects the length of time that calls w...

Page 11: ...cted the 1600A series phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is completed Notes This feature is enabled in the factory default set...

Page 12: ...nown the phone can be set to automatically call Viking technical support for assistance With DIP switch 3 set to OFF programming mode pushing the CALL button will cause the 1600A Series phone to call...

Page 13: ...utomatically reduce the mic sensitivity when the location becomes noisy This Automatic Noise Canceling ANC feature will allow speakerphone two way communications to work properly even when subjected t...

Page 14: ...ction D the phone stays in two way talk mode allowing two way conversation When calling the Central Station number memory position 05 the phone is in a listen only mode in order to interpret the hand...

Page 15: ...B Central Station Operation After the HELP CALL button on the 1600A Series phone has been pressed the 1600A Series phone will begin to dial If a voice number is programmed in memory locations 00 04 th...

Page 16: ...CONTACT VIKING TECHNICAL SUPPORT AT 715 386 8666 Our Product Support Department is available for assistance Monday Friday 8am 5pm central time So we can give you better service before you call please...