background image

2

Features Overview

VIKING

©

INFO HELP

CALL

CONNECTED

Speaker Screen:

  Speaker screen with 

0.018" wide slots to prevent punctures 
from paperclips, etc.

Faceplate:

  Marine grade 316 stainless steel.

Speaker:

  Mylar speaker with rubber 

gasket to maintain water-tight seal and 
eliminate water deterioration.

Mounting Screws:

  (4) T-10 Torx head 

stainless steel, flat head, security 
screws and drive bit included.

Red Call Connected LED

Microphone:

  Omni-directional 

microphone with protective 
water-resistant cloth.

E

M

E

R

G

E

N
C

Y

CALL

CONNECTED

PUSH FOR

VIKING

©

HELP

“HELP” Push to Call Button:

  Solid 316 

stainless steel internally sealed per IP67.

“INFO” Push to Call Button 
(models E-1600A-AST2EWP 
and E-1600A-BLT2EWPonly):

  

Solid 316 stainless steel 
internally sealed per IP67.

Grade 2 Braille Label

Laser Etched Graphics

Mounting Screws:

  (4) T-10 Torx head stainless steel, 

flat head, security screws and drive bit included.

SL-2 Strobe/Beacon:

  Blue shatter resistant polycarbonate 

lens. Designed to meet IP66 ingress Protection Rating.

Tower Chassis:

  8 gauge (0.125” thick) aluminum with 

weather-resistant high-visibility yellow powder paint.

Rain Guard

(included)

EMERGENCY

 or 

ASSISTANCE

 lettered in 

black on three sides of the tower chassis.

Rear View of the 

Phone Panel

Ring Connector

(included)

* Earth Ground

(optional)

1600A Emergency Phone Board

BLK-4 Control Module

Marine grade 316 stainless steel faceplate 
and push button switch (sealed per IP67)

1

3

2

ON

1

2

ON

Front View of the

Phone Panel

Summary of Contents for E-1600A-AS T2EWP

Page 1: ...s 9 1 kg Mounting Surface mount to rigid wall or post Operating Temperature 15 F to 130 F 26 C to 54 C Humidity Up to 100 Strobe Flash Rate 60 flashes per minute default see page 7 for more info Maxim...

Page 2: ...O Push to Call Button models E 1600A AST2EWP and E 1600A BLT2EWPonly Solid 316 stainless steel internally sealed per IP67 Grade 2 Braille Label Laser Etched Graphics Mounting Screws 4 T 10 Torx head s...

Page 3: ...th wire exiting left side of panel Step 1 Mount the tower phone approximately 42 above the floor to a flat sturdy surface using 5 16 hardware Note Flat washers should be used on the main mounting bolt...

Page 4: ...r View of Legacy SL 1 Strobe Light included with 2012 and older E 1600A BLT EWP models Black Red Negative Positive 1 3 3 2 ON ON Note To increase surge protection loosen the PCB mounting screw labeled...

Page 5: ...he load to snub high voltage spikes With DIP switch 4 ON wet switched 12VDC 100mA maximum will be output on the yellow wire and GND on the black wire 2 Loop Off hook Indication Only Place DIP switch 1...

Page 6: ...o 6 Brightest After selecting Programming Feature 5 Beacon Brightness wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting Touch and hold the Green Control wire to t...

Page 7: ...ects an incoming ring signal it activates a set of normally open or normally closed contacts and turns on the 12VDC output for activating the provided strobe light With the Ring Cadence mode off DIP s...

Page 8: ...When the 1600A Series phone answers a double beep should then be heard and will automatically enter the programming mode Step 5 When finished programming move DIP switch 3 back to the ON position see...

Page 9: ...he security office can display the number using a Touch Tone decoder To program the I D number enter the desired number followed by 20 Example To store 333 as the I D number enter 3 3 3 2 0 2 INFO Spe...

Page 10: ...ignal busy signal silence or return to dial tone to hang up Use chart at the right Note The factory default is 3 minutes Setting C Silence Time Out This feature selects the length of time that calls w...

Page 11: ...cted the 1600A series phone will dial the next programmed speed dial number and continue to cycle through the numbers until a call is completed Notes This feature is enabled in the factory default set...

Page 12: ...nown the phone can be set to automatically call Viking technical support for assistance With DIP switch 3 set to OFF programming mode pushing the CALL button will cause the 1600A Series phone to call...

Page 13: ...utomatically reduce the mic sensitivity when the location becomes noisy This Automatic Noise Canceling ANC feature will allow speakerphone two way communications to work properly even when subjected t...

Page 14: ...ction D the phone stays in two way talk mode allowing two way conversation When calling the Central Station number memory position 05 the phone is in a listen only mode in order to interpret the hand...

Page 15: ...B Central Station Operation After the HELP CALL button on the 1600A Series phone has been pressed the 1600A Series phone will begin to dial If a voice number is programmed in memory locations 00 04 th...

Page 16: ...CONTACT VIKING TECHNICAL SUPPORT AT 715 386 8666 Our Product Support Department is available for assistance Monday Friday 8am 5pm central time So we can give you better service before you call please...