PROBLEM
POSSIBLE CAUSE
CORRECTION
E2 error code along with audible alarm (6 /per
min.) - condenser low amp
Condenser fan motor wire disconnected.
Faulty condenser fan motor.
Faulty power board.
Check wiring to fan motor
Replace condenser fan motor.
Replace power board.
E3 error code along with audible alarm (6 /per
min.) - upper thermistor
Disconnected thermistor plug
Shorted thermistor
Faulty thermistor
Check connection on rear of user interface board.
Ohm and replace if necessary.
Ohm and replace if necessary
E4 error code along with audible alarm (6 /per
min.) - lower thermistor
Disconnected thermistor plug.
Shorted thermistor.
Faulty thermistor.
Check connection on rear of user interface board.
Ohm and replace if necessary.
Ohm and replace if necessary
Service Diagnostics Mode is not engaging
WARMER keypad was not depressed and held
firmly while pressing the COLDER keypad 4
times within 5 seconds.
Depress and hold WARMER keypad firmly
while pressing the COLDER keypad 4 times
within 5 seconds. Audible beep will sound at
every key stroke
Service Diagnostics Mode is not disabling
WARMER keypad was not depressed and held
firmly while pressing the COLDER keypad 4
times within 5 seconds.
Depress and hold WARMER keypad firmly
while pressing the COLDER keypad 4 times
within 5 seconds. Audible beep will sound at
every key stroke
Service Diagnostics Mode is automatically
disabled
After 5 minutes of no keypad functions, the
Diagnostics Mode will automatically disable
Re-enter the diagnostics mode to continue.
Compartment temperature to warm.
Frosted evaporator coil.
Compartment fan not working
Return air damper not closing-tape securing
damper has come loose.
Heater/fan assembly not disabling
Air leak at rear of cabinet.
Bad door gasket / seal.
Divider seal on door is by-passing air.
Open or out of range thermistor.
Broken or loose connection on communication
cable, U/I board, or main power board.
Older version of software is installed.
Replace, current version is 1.9
Replace compartment fan.
Remove divider and repair.
Faulty main power board. Replace
Remove back panel to make sure all wire and
tubing portals are properly sealed. Seal using
permagum or RTV.
Check for worn or torn gasket - replace.
Gasket pulling away from inner door pan - seal
with superglue or RTV.
Inspect and replace door divider seal if needed.
Ohm and replace thermistor if needed
Check cable connections at U/I board and main
power board.
Check wire continuity from one end of the com
-
munication cable harness to the opposite - OL
reading means a broken harness - replace.
A close visual inspection of all terminal block
pins could reveal any broken connections.
Compartment temperature to cold
Bad fan/heater assembly
Check heater continuity - Resistance of heater/
fan assembly should be 7.5 Ohms @70
°
F.
61
11.1 Problem / Cause / Correction, continued.
2010 - Viking Preferred Service
SMR-0005
Summary of Contents for DFUW244CL
Page 6: ...Section 1 Introduction to Dual Zone 2010 Viking Preferred Service SMR 0005 ...
Page 10: ...Section 2 Dual Zone Characteristics 2010 Viking Preferred Service SMR 0005 ...
Page 16: ...Section 3 Refrigeration Systems 2010 Viking Preferred Service SMR 0005 ...
Page 27: ...Section 4 TruProtect Control Diagnostics 2010 Viking Preferred Service SMR 0005 ...
Page 30: ...Section 5 Mechanical System Components 2010 Viking Preferred Service SMR 0005 ...
Page 38: ...Section 6 Structural Components 2010 Viking Preferred Service SMR 0005 ...
Page 42: ...Section 7 Electrical Components 2010 Viking Preferred Service SMR 0005 ...
Page 50: ...Section 8 Control Components 2010 Viking Preferred Service SMR 0005 ...
Page 54: ...Section 9 Wiring 2010 Viking Preferred Service SMR 0005 ...
Page 57: ...52 J110 J111 J112 J2 J1 J4 J7 J3 9 3 Main Power Board 2010 Viking Preferred Service SMR 0005 ...
Page 58: ...9 4 User Interface 53 2010 Viking Preferred Service SMR 0005 ...
Page 59: ...Section 10 Reference Charts 2010 Viking Preferred Service SMR 0005 ...
Page 64: ...Section 11 Trouble Shooting Guide 2010 Viking Preferred Service SMR 0005 ...
Page 68: ...Section 12 Reference Photos 2010 Viking Preferred Service SMR 0005 ...
Page 71: ...2010 Viking Preferred Service SMR 0005 ...
Page 72: ...2010 Viking Preferred Service SMR 0005 ...
Page 74: ...2010 Viking Preferred Service SMR 0005 ...
Page 75: ...2010 Viking Preferred Service SMR 0005 ...
Page 76: ...2010 Viking Preferred Service SMR 0005 ...
Page 77: ...2010 Viking Preferred Service SMR 0005 ...
Page 78: ...2010 Viking Preferred Service SMR 0005 ...
Page 79: ...2010 Viking Preferred Service SMR 0005 ...
Page 80: ...2010 Viking Preferred Service SMR 0005 ...
Page 81: ...2010 Viking Preferred Service SMR 0005 ...
Page 84: ...2010 Viking Preferred Service SMR 0005 ...