7.1 Fans
7.1.1 Condenser Fan
The condenser fan is used to force air over the condenser coil. The condenser fan cycles on and off si
-
multaneously along with the compressor.
1)
Make sure that the motor shaft turns freely. The blade can be turned in either direction to verify
that the shaft is not seized or the blade binding. Watch the blade and listen for any noise that
might indicate a problem.
2)
Check resistance between the terminals of the motors power cord. Replace the motor if the wind
ings are shorted (open).
3)
Check for continuity between each lead of the power wires to the motors casing. If the motor is
grounded there will be a continuity reading.
4)
Check amp draw. Typical current draw will be approximately 0.15 without any resistance on the
fan. A current draw exceeding 0.19 will be an indication that the motor or fan blade is not turning
freely.
7.1.1.1 Removal of the Condenser Fan Motor
1) Remove all screws around the perimeter of the cabinet. Do not remove the screws in the slotted
area. (See figure 12.3)
2) To loosen the rear of the mechanical assembly, remove both hex screws at each lower back corner
(See figures 12.4).
3) Remove the two Phillips screws and remove the front grille (See figure 12.5).
4) To loosen the front of the mechanical assembly, remove both Phillips screws that secure the front
corners (See figure 12.6).
5)
CAUTION
, (See figures 12.7 & 12.8) before sliding out the mechanical assembly please read the
following carefully. To avoid kinking of any system tubing do not slide the mechanical section
forward farther then 6” maximum. Doing so may kink any or all of the following: discharge line
at the compressor, suction line at the compressor, suction line as it exits the rear of the cabinet.
6)
Remove condenser fan by removing the four screws on the fan mounting base plate.
7)
Remove the tinnerman clip from the motor shaft and remove the fan blade and rubber silencer.
8)
Remove the fan motor from the bracket.
9)
Disconnect the electrical leads.
SEE PHOTO SECTION FOR REFERENCE TO ABOVE MENTIONED FIGURES
38
2010 - Viking Preferred Service
SMR-0005
Summary of Contents for DFUW244CL
Page 6: ...Section 1 Introduction to Dual Zone 2010 Viking Preferred Service SMR 0005 ...
Page 10: ...Section 2 Dual Zone Characteristics 2010 Viking Preferred Service SMR 0005 ...
Page 16: ...Section 3 Refrigeration Systems 2010 Viking Preferred Service SMR 0005 ...
Page 27: ...Section 4 TruProtect Control Diagnostics 2010 Viking Preferred Service SMR 0005 ...
Page 30: ...Section 5 Mechanical System Components 2010 Viking Preferred Service SMR 0005 ...
Page 38: ...Section 6 Structural Components 2010 Viking Preferred Service SMR 0005 ...
Page 42: ...Section 7 Electrical Components 2010 Viking Preferred Service SMR 0005 ...
Page 50: ...Section 8 Control Components 2010 Viking Preferred Service SMR 0005 ...
Page 54: ...Section 9 Wiring 2010 Viking Preferred Service SMR 0005 ...
Page 57: ...52 J110 J111 J112 J2 J1 J4 J7 J3 9 3 Main Power Board 2010 Viking Preferred Service SMR 0005 ...
Page 58: ...9 4 User Interface 53 2010 Viking Preferred Service SMR 0005 ...
Page 59: ...Section 10 Reference Charts 2010 Viking Preferred Service SMR 0005 ...
Page 64: ...Section 11 Trouble Shooting Guide 2010 Viking Preferred Service SMR 0005 ...
Page 68: ...Section 12 Reference Photos 2010 Viking Preferred Service SMR 0005 ...
Page 71: ...2010 Viking Preferred Service SMR 0005 ...
Page 72: ...2010 Viking Preferred Service SMR 0005 ...
Page 74: ...2010 Viking Preferred Service SMR 0005 ...
Page 75: ...2010 Viking Preferred Service SMR 0005 ...
Page 76: ...2010 Viking Preferred Service SMR 0005 ...
Page 77: ...2010 Viking Preferred Service SMR 0005 ...
Page 78: ...2010 Viking Preferred Service SMR 0005 ...
Page 79: ...2010 Viking Preferred Service SMR 0005 ...
Page 80: ...2010 Viking Preferred Service SMR 0005 ...
Page 81: ...2010 Viking Preferred Service SMR 0005 ...
Page 84: ...2010 Viking Preferred Service SMR 0005 ...