During a defrost cycle the compressor, condenser fan, and the coldest compartment fan are off. The
compartment fan in the warmest compartment will run for a total of 30 minutes.
7.1.2.2 Replacing Compartment Fans
1)
Replace compartment fans by removing the 2 Phillips screws on each side of fan assembly (See
figure 12.19).
2)
Pull fan away from evaporator cover to disconnect Molex connection.
3)
Depress the release clips on each side of the Molex plug and separate from the wire harness con-
nection.
4)
Reverse above steps to replace.
7.1.3 Heater / Fan Assembly
There is a heater / fan assembly located inside each compartment. These heater / fans are used to add
heat into the specific compartment as needed to maintain the desired set-point.
During a call for heat (cut-in) the compartment fan will de-energize. The compartment heater / fan for
that compartment will then energize.
The compressor and condenser fan will continue to run if the other compartment is still calling for cool
-
ing.
7.1.3.1 Heater / Fan Operation
Typical compartment call for heat cycle:
At cut-in temperature:
On:
Heater / Fan
Off:
Compressor, Condenser Fan, & Compartment Fan
At cut-out temperature:
Off:
Compressor, Condenser Fan, Compartment Fan, Heater / Fan
A call for heating cycle is terminated if the set point is changed to less than 49˚F.
If a compartment has a call for heat while the other compartment is satisfied.
The compressor and condenser fan will de-energize.
The heater / fan for the call for heat compartment will energize.
The compartment fan for the satisfied compartment will remain off to prevent the circulation of non-
cooled evaporator air from being circulated into the satisfied compartment.
SE
E PHOTO SECTION FOR REFERENCE TO ABOVE MENTIONED FIGURES
40
2010 - Viking Preferred Service
SMR-0005
Summary of Contents for DFUW244CL
Page 6: ...Section 1 Introduction to Dual Zone 2010 Viking Preferred Service SMR 0005 ...
Page 10: ...Section 2 Dual Zone Characteristics 2010 Viking Preferred Service SMR 0005 ...
Page 16: ...Section 3 Refrigeration Systems 2010 Viking Preferred Service SMR 0005 ...
Page 27: ...Section 4 TruProtect Control Diagnostics 2010 Viking Preferred Service SMR 0005 ...
Page 30: ...Section 5 Mechanical System Components 2010 Viking Preferred Service SMR 0005 ...
Page 38: ...Section 6 Structural Components 2010 Viking Preferred Service SMR 0005 ...
Page 42: ...Section 7 Electrical Components 2010 Viking Preferred Service SMR 0005 ...
Page 50: ...Section 8 Control Components 2010 Viking Preferred Service SMR 0005 ...
Page 54: ...Section 9 Wiring 2010 Viking Preferred Service SMR 0005 ...
Page 57: ...52 J110 J111 J112 J2 J1 J4 J7 J3 9 3 Main Power Board 2010 Viking Preferred Service SMR 0005 ...
Page 58: ...9 4 User Interface 53 2010 Viking Preferred Service SMR 0005 ...
Page 59: ...Section 10 Reference Charts 2010 Viking Preferred Service SMR 0005 ...
Page 64: ...Section 11 Trouble Shooting Guide 2010 Viking Preferred Service SMR 0005 ...
Page 68: ...Section 12 Reference Photos 2010 Viking Preferred Service SMR 0005 ...
Page 71: ...2010 Viking Preferred Service SMR 0005 ...
Page 72: ...2010 Viking Preferred Service SMR 0005 ...
Page 74: ...2010 Viking Preferred Service SMR 0005 ...
Page 75: ...2010 Viking Preferred Service SMR 0005 ...
Page 76: ...2010 Viking Preferred Service SMR 0005 ...
Page 77: ...2010 Viking Preferred Service SMR 0005 ...
Page 78: ...2010 Viking Preferred Service SMR 0005 ...
Page 79: ...2010 Viking Preferred Service SMR 0005 ...
Page 80: ...2010 Viking Preferred Service SMR 0005 ...
Page 81: ...2010 Viking Preferred Service SMR 0005 ...
Page 84: ...2010 Viking Preferred Service SMR 0005 ...