Coding
Coding 1
(continued)
Coding in the factory set condition
Possible change
Charging
(continued)
Day hopper idle runtime (autom. charging)
2C:...
Rotary lock valve emptying
time in minutes before
vacuum module starts.
Code is only available for
charging with vacuum
module.
2C:...
to
2C:...
Setting range in min
Screw conveyor delay
2E:...
Delay in seconds
2E:0
to
2E:100
Setting range in sec.
Discharge cycle - ON
30:...
Discharge cycle in seconds
(discharge runs for ... sec.)
30:2
to
30:30
Setting range in sec.
Discharge cycle - OFF
31:...
Discharge pause in seconds 31:...
Discharge does not pause: Constant
31:1
to
31:100
Setting range in sec. (discharge pause
adjustable from 1 to 100 sec.)
Discharge delay
32:...
Delay in seconds
32:0
to
32:100
Setting range in sec.
External charging cycle - ON
40:...
External charging cycle in
seconds (external charging
runs for ... sec.)
40:2
to
40:30
Setting range in sec.
External charging cycle - OFF
41:...
External charging pause in
seconds
41:0
External charging does not pause:
Constant operation
41:1
to
41:100
Setting range in sec.
(pause in external charging adjustable
from 1 to 100 sec.)
External charging delay
42:...
External charging delay in
seconds
42:0
to
42:100
Setting range in sec.
Reheating suppression buffer tank temperature
33:...
Set minimum buffer tank
temperature when being
heated by the solar system
(only available when the
solar system is connected
to the Vitoligno 300-C.
33:0
No reheating suppression