Commissioning, Inspection and Maintenance
Cleaning Secondary Heating Surfaces
Note:
Clean the secondary heating surfaces at least once
per heating season.
1. Remove top panel
A
. Remove the 2 rear screws for
this
purpose.
2. Remove thermal insulation mat
B
.
3. Remove cleaning cover
C
.
4. Pull out cleaning spirals
D
.
5. Clean reversing chambers
E
and secondary heating
surfaces
(flues)
F
with a cleaning brush and vacuum
cleaner.
6. Reassemble in reverse order.
Cleaning the Flue Pipe
Removing Flue Ash from the Chimney
The flue pipe should be cleaned annually or after the
consumption of 33,000 lb. (15,000 Kg) of pellets.
The flue ash from the chimney should be removed annually or
after the consumption of 33,000 lb. (15,000 Kg) of pellets.