1.
Flip up control unit
A
.
2.
Release four wing nuts and remove
fan unit
B
. Check the gasket for
tight fit and condition.
3.
Clean impeller
C
with spatula.
Vacuum fly ash from the impeller,
lid and fan box.
4.
Lift the fan box
D
at the front and
lift out.
5.
Cleaning the flue pipe.
6.
Vacuum the upper area of second-
ary heating surface
E
.
7.
Assemble in reverse order.
Note
Tighten the wing nuts diagonally.