61
5603 878 - 04
Vitoflex 300-RF Installation & Operating
Operation
ECOTRONIC Control System
(continued)
Screen number Screen text
Parameter description
Factory setting
(41)
Extraction system 2
.....
delay
Switch-on delay of the extraction system 2
(e.g. spring extraction system, pellet extraction auger)
Only display if:
Extraction system 2 available
3 sec
(42)
Extraction system 2
.....
pulse
Pulse of the cycle extraction system 2
(e.g. spring extraction system, pellet extraction auger)
Only display if:
Extraction system 2 available or extraction system 1
available with clock circuit
5 sec
(43)
Extraction system 2
.....
Pause
Pause of the cycle extraction system 2
(e.g. spring extraction system, pellet extraction auger)
Only display if:
Extraction system 2 available or extraction system 1
available with clock circuit
0 sec
(44)
Extraction system 1
Hydraulics
delay
Switch-on delay of the hydraulic unit extraction system 1
Only display if:
Extraction system 1 with hydraulic unit available
5 sec
(45)
Extraction system 2
Hydraulics
delay
Switch-on delay of the hydraulic unit extraction system 2
Only display if:
Extraction system 2 with hydraulic unit available
5 sec
(46)
Extraction system 1
Horizontal extraction
system agitator
delay
Switch-on delay of the agitator of the horizontal
extraction system 1
Only display if:
Extraction system 1 available as horizontal extraction
system
5 sec
(47)
Extraction system 2
Horizontal extraction
system agitator
delay
Switch-on delay of the agitator of the horizontal
extraction system 2
Only display if:
Extraction system 2 available as horizontal extraction
system
5 sec
(50)
Silo filling
If the silo filling function should be started (only possible
if the boiler has been out of operation for at least 1 hour).
No
5.2 Loading Service Menu
Menu designation: - Loading Service
Access menu: - Hold down
O
, press
F4
briefly
Exit menu: - Press
F4
briefly or automatically after 60 seconds
Note:
Depending on the design and setting, some menus and text do not appear.
Screen number Screen text
Parameter description
Factory setting
(1)
In-feed auger
Combustion chamber
fill time
Fill time of the combustion chamber:
With a cold boiler the in-feed auger is filled for this respective
duration whilst the combustion chamber is heated
130 sec
(2)
In-feed auger
Auger fill time
In-feed auger fill time:
With a warm boiler the in-feed auger is filled for this
respective duration while the combustion chamber is heated
120 sec
(5)
In-feed auger
light barrier delay
Delay of the in-feed auger light barrier
500 ms
5.1 Loading menu
(continued)