Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
59:0
DHW cylinder loading:
Starting point -2.5 K
Stopping point +2.5 K
59:1
to
59:10
Starting point adjustable
from 1 to 10 K below the
set value
60:10
During DHW loading,
the boiler water tem-
perature is a maximum
of 20 K higher than the
set DHW temperature
60:5
to
60:25
The difference between
the boiler water tempera-
ture and the set DHW
temperature is adjustable
from 10 to 50 K
62:2
Circulation pump with 2
minutes run-on time
62:0
Circulation pump without
run-on
62:1
to
62:15
Run-on time adjustable
from 1 to 15 minutes
63:0
*
1
Without auxiliary func-
tion for DHW loading
63:1
Additional function: 1 x
daily
63:2
to
63:14
Every 2 to every 14 days
63:15
2 x daily
65:...
Information regarding
the type of diverter
valve (not adjustable)
65:0
Without diverter valve
65:1
Diverter valve by Viess-
mann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
6C:100
Set speed internal DHW
loading pump 100 %
6C:0
to
6C:100
Set speed adjustable
from 0 to 100 %
6F:100
Max. output during
DHW loading 100 %,
defaulted by the boiler
coding card
6F:0
to
6F:100
Max. output during DHW
loading adjustable from 0
to 100 %
Code 2
(cont.)
48
Coding
56
92
548
GB
*1
Only for constant temperature control units.
Summary of Contents for VITODENS 333
Page 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Page 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Page 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Page 131: ...131 5692 548 GB ...