4.
Press
L
and
G
simultaneously
for approx. 1 second.
Coding is terminated.
Overall summary
The coding addresses are grouped in accordance with the following
function
ranges
. The respective function range is displayed.
Scroll through the ranges in the following sequence with
a
or
b
.
Function range
Coding addresses
System design
00
Boiler/burner
06 to 54
DHW
56 to 73
General
76 to 9F
Boiler circuit (heating circuit A1 without
mixer)
A0 to F7
Mixer circuit (heating circuit M2 with mixer)
A0 to F7
Note
Codes, which are not relevant because of the equipment level of your heating
system or because of settings of other codes, will not be displayed.
For heating systems with one heating circuit without mixer and one heating cir-
cuit with mixer, initially the possible coding addresses A0 to F7 are scrolled for
the heating circuit without mixer A1, then those for the heating circuit with mixer
M2.
Code 2
(cont.)
42
Coding
56
92
548
GB