Coding in
the as
delivered
condition
Address:
value
Function mode
Coding
change
Address:
value
Possible change
7F:1
*
1
Detached house
7F:0
Multi-occupancy house
Separate adjustment for
holiday program and time
program for DHW load-
ing, as option
80:1
With 5 seconds time
delay for fault message;
message will be issued,
if a fault persists for at
least 5 seconds
80:0
Without time delay
80:2
to
80:199
Time delay adjustable
from 10 to 995; 1 step =
5 s
81:1
Automatic change
between summer and
winter
81:0
Manual summer/winter
changeover
81:2
The application of the
radio clock module will be
recognised automatically
81:3
Accept time via LON
88 :0
Temperature display in
°Celsius
88 :1
Temperature display in
Fahrenheit
8A:175
Do not adjust
90:128
Time constant for calcu-
lating adjusted outside
temperature 21.3 h
90:0
to
90:199
Quick (low values) or
slow (high values) match-
ing of flow temperature
subject to set value if the
outside temperature
changes;
1 step = 10 min.
Code 2
(cont.)
50
Coding
56
92
548
GB
*1
Only for weather-compensated control unit.
Summary of Contents for VITODENS 333
Page 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Page 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Page 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Page 131: ...131 5692 548 GB ...