Example 2: Modifying the reduced
room temperature from 5 °C to 14 °C
A
Boiler water or flow temperature
in °C
B
Outside temperature in °C
C
Set room temperature in °C
D
Heating circuit pump OFF
E
Heating circuit pump ON
2.
Call up the set night temperature
with
E
.
3.
Change this value with
a
and
b
.
4.
Confirm the set value with
d
.
Instructing the system user
The system installer must hand the operating instructions to the system user
and instruct them in the operation of the system.
Scanning and resetting the maintenance display
The red fault indicator flashes when the limits set via coding address 21 and 23
have been reached. As regards the operating interface display:
&
for constant temperature control units, the hours run (subject to setting) or the
given time interval and the clock symbol will flash
&
for weather-compensated control units "Maintenance" flashes.
Note
Set code 24:1 and then code 24:0, if maintenance is implemented before main-
tenance is displayed; the set maintenance parameters for hours run and interval
are then reset to 0.
Further details regarding the individual steps
(cont.)
37
Initial start-up, inspection, maintenance
56
92
548
GB
Summary of Contents for VITODENS 333
Page 114: ...Parts lists cont 114 Parts lists 5692 548 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 548 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 548 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 548 GB ...
Page 118: ...Parts lists cont 118 Parts lists 5692 548 GB ...
Page 119: ...Parts lists cont 119 Parts lists 5692 548 GB ...
Page 131: ...131 5692 548 GB ...