124
Dis-
played
fault
code
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
50
X
X
No DHW heat-
ing
Short circuit,
cylinder tem-
perature sen-
sor
Check the cylinder
temperature sen-
sor (see
page 140)
51
X
X
No DHW heat-
ing
Short circuit,
outlet temper-
ature sensor
Check the outlet
temperature sen-
sor (see
page 142)
58
X
X
No DHW heat-
ing
Lead break,
cylinder tem-
perature sen-
sor
Check the cylinder
temperature sen-
sor (see
page 140)
59
X
X
No DHW heat-
ing
Lead break,
outlet temper-
ature sensor
Check the outlet
temperature sen-
sor (see
page 142)
A7
X
Control mode
as per deliv-
ered condition
Programming
unit faulty
Replace program-
ming unit
A8
X
Burner blocked
The venting
program is star-
ted automati-
cally (see
page 77)
Air lock in the
internal circu-
lation pump
or minimum
flow rate not
achieved
Vent the system if
the fault message
continues to be dis-
played
A9
X
If a heating cir-
cuit with mixer
is connected,
the burner op-
erates at its
lower heating
output.
If only one
heating circuit
without mixer is
connected, the
burner is
blocked
Internal circu-
lation pump
blocked
Check the circula-
tion pump
Troubleshooting
Fault codes
(cont.)
5773 216 GB
Summary of Contents for Vitodens 222-F B2TA series
Page 12: ...12 2 5 1 4 2x 3 Installing the boiler Removing the front panels 5773 216 GB...
Page 13: ...13 1 2 SW17 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation...
Page 31: ...31 4 1 5 2 2x 3 Installing the boiler Fitting the front panels 5773 216 GB Installation...
Page 194: ...194 5773 216 GB...
Page 195: ...195 5773 216 GB...