![Viessmann VITOCAL 300-G PRO Type BW 2150 Installation And Service Instructions Manual Download Page 109](http://html1.mh-extra.com/html/viessmann/vitocal-300-g-pro-type-bw-2150/vitocal-300-g-pro-type-bw-2150_installation-and-service-instructions-manual_1017894109.webp)
109
Parameters
Code
Delivered condi-
tion
Initial
commis-
sioning
Electric booster heater
Enable instantaneous heating water
heater
7900
0
Enable instant. heating water heater for
central heating
7902
1
Max. output instantaneous heating water
heater
7907
3
Output for instant. heating water heater at
power-OFF
790A
0
Dual mode temp. instant. heating water
heater
790B
100 (
≙
10 °C)
Internal hydraulics
Heat pump for drying a building
7300
0
Time program for screed drying
7303
0
Set flow temperature, external demand
730C
500 (
≙
50 °C)
Operating mode primary pump
7320
Never adjust.
Operating mode secondary pump
7340
Never adjust.
Heating water buffer cylinder
Enable buffer cylinder/low loss header
7200
0
Temp. in operating status fixed value for
buffer cyl
7202
500 (
≙
50 °C)
Hysteresis temperature heating buffer
cylinder
7203
50 (
≙
5 K)
Max. temperature buffer cylinder
7204
600 (
≙
60 °C)
Temp. limit op. status fixed value for buf-
fer cylinder
7208
100 (
≙
10 °C)
Heating circuit 1
Standard room temperature
2000
200 (
≙
20 °C)
Reduced room temperature
2001
160 (
≙
16 °C)
Remote control
2003
0
Heating curve level
2006
0 (
≙
0 K)
Heating curve slope
2007
6 (
≙
0.6)
Influence room temperature hook-up
200A
10
Room temperature hook-up
200B
3
Max. flow temperature heating circuit
200E
400 (
≙
40 °C)
Room temperature in party mode
2022
200 (
≙
20 °C)
Commissioning/service reports
Commissioning/service reports
(cont.)
5772 458 GB
Service