650 mm
≥
a
500 kg
650 mm
≥
V 20 m³
≥
A
B
2 °C
35 °C
≥
≥
≥
A
Vitocal 160-A
B
Siphon for condensate drain
With circulating cover a = 2100 mm
With extract cover
a = 2200 mm
Installation room requirements
■ The installation room must be dry and safe from the risk of frost.
■ Circulated and extract air must be free of dust and grease and must
not be contaminated with high amounts of halogenated hydrocar-
bons.
■ Min. room volume 20 m
3
.
■ Min. load-bearing capacity of the floor 500 kg.
■ Temperature range 2 °C to 35 °C.
■ The appliance must be accessible for maintenance purposes.
■ Provide a drain pipe for draining the condensate.
The following are ideal locations:
■ Utility room and domestic offices on the ground floor
■ Cellar
The following locations should be avoided:
■ Drying rooms (for circulating mode)
■ Rooms immediately next to bedrooms and quiet rooms
Design information
(cont.)
VITOCAL 160-A
VIESMANN
19
5822 485 GB