11
Standard room temperature
D
E
B
C
A
110
20°C
26°C
-20°C
26
20
Adjustment of the standard room tem-
perature from 20 to 26 °C
A
Flow temperature in °C
B
Outside temperature in °C
C
Set room temperature in °C
D
Heating circuit pump OFF
E
Heating circuit pump ON
Press the following keys in the standard
menu:
1.
|
/
~
for
"Heating"
.
2.
d
to confirm.
3.
Ù
/
Ú
for selecting the heating cir-
cuit.
4.
|
/
~
for
"Set room temperature"
5.
d
to confirm.
6.
|
/
~
for the required temperature.
7.
d
to confirm.
Reduced room temperature
3
14
20
C
110
3°C
A
D
E
B
-20°C
14°C
Adjustment of the reduced room temper-
ature from 3 to 14 °C
A
Flow temperature in °C
B
Outside temperature in °C
C
Set room temperature in °C
D
Heating circuit pump OFF
E
Heating circuit pump ON
Press the following keys in the standard
menu:
1.
å
for "Advanced menu".
2.
|
/
~
for
"Heating"
.
3.
d
to confirm.
4.
Ù
/
Ú
for selecting the heating cir-
cuit.
5.
|
/
~
for
"Set red. room temp."
.