Coding in the delivered condition
Possible change
Number of heating circuits used
Number of
HC:2
2 heating circuits instal-
led.
Number of
HC:0
to
Number of
HC:2
possible number of heating
circuits with 1 DHW circuit.
Number of
HC:0
to
Number of
HC:3
possible number of heating
circuits
without
addit.
DHW circuit.
General
Coding
Coding in the delivered condition
Possible change
Detached house/apartment building
7F:1
Detached house, same
holiday program for all
heating circuits
7F:0
Apartment building, holi-
day program can be adjus-
ted separately
Boiler
Coding
Coding in the delivered condition
Possible change
Additional heat source, burner
0A:0
No additional heat source
available
0A:1
Pyromat ECO features an
oil burner
0A:2
External additional heat
source available
Additional heat source, buffer charging operation
0B:0
No
0B:1
Yes
Additional heat source, buffer charging operation up to
0C:60
Temperature in °C at the
upper sensor up to which
the additional heat source
or mounted burner should
charge the buffer
0C:30
to
0C:100
Setting range of between
30 °C and 100 °C.
Codes
Code 1
(cont.)