background image

 

Two Wire Videokit ESVK Series

 

 PrtCode:ESVK_ENG_1.6.doc – Pag.8/44 

25/11/2009

Rev.1.6

SW2 – PRIVACY DURATION TIME 

Switches Status 

4 3 2 1 

Privacy Mode 

(switch 1) 

Privacy Duration 

(switches 2,3) 

OFF OFF 

15 minutes 

OFF ON 

1 hour 

ON OFF 

4 hours 

ON ON 

OFF 

The privacy duration time is set by switches 2 and 3. When enabled the privacy ser-
vice will be disabled when the set time expires or the switch is moved back to off. 

8 hours 

 

  ON 

No privacy time expiration: the privacy service is enabled or disabled only by the 
slide switch. 

 

 

 

SW3 – INTERCOMMUNICATION SETTINGS 

Switches Status 

4 3 2 1 

Intercommunication Mode 

(switch 1) 

Videophone 

Extension 

(switches 2,3) 

OFF OFF 

1 (master) 

OFF ON 

2 (slave) 

ON OFF 

3 (slave) 

ON ON 

OFF 

Intercommunication allowed between videophones (same unit address) inside the 
same flat. To call an extension pick up the handset then press the “door open” button 
as many times as the extension value (Eg. extension 2 two times, 3 three times etc). 

Each intercom/videophone in the same apartment must have a different exten-
sion address, the master address must always be set except when one of the 
intercom/videophone is set for apartment intercommunication (i.e. in a 3 inter-
com/videophone installation, one of the intercom/videophone must have the 
extension address 1 while the others must have different addresses)

 

4 (slave) 

 

OFF OFF ON 

Intercommunication allowed between videophones (different apartment). To call an 
extension pick up the handset then press the “door open” button as many times as 
the address value (Eg. extension 10 ten times, 12 twelve times etc) 

 

 

On installations where there are more than one intercom/videophone in the same apartment and intercommunication between different 
apartments is required, only one intercom/videophone may be set with this function (SW3.1=ON, SW3.2=OFF, SW3.3=OFF). The other inter-
com/videophones in the apartment must be set for local intercommunication with extension addresses “2-4” (slaves). From the inter-
com/videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave 
extensions 2-4 will be able to intercommunicate with each other. 

 

NUMBER OF RINGS 

The number of rings can be set to 3 (factory preset) or 6. 
To change the number of rings proceed as follow: 

Disconnect the power supply from the system; 

Short the terminals “LB” and “GND”; 

Reconnect the power supply to the system checking the privacy on LED and then remove the short between terminals “LB” and “GND”; 

The number of LED flashes will be 1 for 3 rings or 2 for 6 rings. 

Each time this operation is carried out the number of rings is switched between the values 3 and 6. 

 
 

SIGNALS ON CONNECTION TERMINALS 
Signal Description 
BUS 
BUS 

Bus contacts 

LED- 

Door open LED ground signal input 

LED+ 

Door open LED power supply input (+12Vdc) 

GND 

Ground signal 

GND 

Ground signal 

AL 

Alarm input (not implemented) 

LB 

Local Bell contact (put a push button between this terminal and the relevant GND terminal) 

 

 
 
 
 
 
 

SPECIFICATION 

Housing/Mounting 

3000 Series Intercoms / direct wall mounting 

Push Buttons 

Yes, two 

Programming 

Yes, carried out by the dip-switches inside the intercom 

Controls 

Call tone volume and privacy ON-OFF switch 

Power Supply 

Supplied by the BUS line 

Working Temperature 

-10 +50ºC 

 

 
 

CUSTOMER SUPPORT INFORMATION 

All Countries Customers 

UK Customers 

VIDEX Electronics S.p.A. 

www.videx.it

 – 

[email protected]

 

Tel.+39 0734 631669 

Fax +39 0734 632475 

VIDEX Security LTD 

www.videx-security.com

 

Tech Line 0191 224 3174 

Fax 0191 224 1559 

 

 

 

The product is CE marked demonstrating its conformity and  is for distribution within all 
member states of the EU with no restrictions. 
This product follows the provisions of the European Directives  
89/336/EEC & 92/31/EEC (EMC),  
73/23/EEC (LVD) and 93/68/EEC (CE marking). 

Il prodotto è marchiato CE a dimostrazione della sua conformità e può essere distribuito 
liberamente all’interno dei paesi membri dell’unione europea EU. 
Questo prodotto è conforme alle direttive Europee 
89/336/EEC & 92/31/EEC (EMC), 
73/23/EEC (LVD) e 93/68/EEC (Marcatura CE). 

 

Summary of Contents for 2 Wire

Page 1: ...Edition 2009 Rev 1 6 ...

Page 2: ......

Page 3: ...TERCOM FOR VX2300 16 ART 317 20 FOUR WAY DISTRIBUTION BOX 20 ART 318 21 TWO WAY PASSIVE DISTRIBUTION BOX 21 ART 2315 22 BUS BOOSTER AND VIDEO SIGNAL AMPLIFIER 22 ART 2301N 23 ENTRANCES EXCHANGER FOR VX2300 DIGITAL SYSTEMS 23 ART 2305 24 EXTENSION RELAY FOR VX2300 DIGITAL SYSTEMS 24 ART 2380 25 INTERFACE 2 WIRE TO 4 1 AUDIO SYSTEM 25 ART 2321 2321 P 27 POWER SUPPLIES FOR VX2300 27 ART 2322 28 POWER...

Page 4: ...the electric lock 3 contacts common normally open and normally closed It can work also as capacitor discharge to supply directly the electric lock The call buttons from 1 to a maximum of 2 depending on the module version The illumination LEDs for the card name holder The camera comprised of illumination LEDs Module Details a Camera with illumination LEDs b Loudspeaker c Card name holder d Call pus...

Page 5: ...normally open contact BUS Bus connection terminals C Door open relay normally closed contact PTE Push to exit active low input C Electric lock capacitor discharge output GND Ground VAUX 35Vdc power supply input if used the module is powered locally and not from the BUS GND Ground NC Door open relay normally closed contact To use the electric lock with capacitor discharge make a short between C and...

Page 6: ...N A Programming N A Controls N A Power Supply N A Working Temperature 10 50ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www videx security com Tech Line 0191 224 3174 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution ...

Page 7: ...turn off when the time expires f Call tone volume control 3 levels DIP SWITCHES AND JUMPERS FIG 2 SW1 Switches from 1 to 7 are used for unit address from 1 to 127 binary coded Last switch 8 is not used SW2 Switches 1 2 and 3 are used to set privacy duration time Switch 4 is not used SW3 Switches 1 2 and 3 are used to for intercommunication settings Switch 4 is not used S1 Impedance terminator The ...

Page 8: ...addresses 2 4 slaves From the inter com videophone set for intercommunication with other apartments it will be not possible to intercommunicate within the apartment but slave extensions 2 4 will be able to intercommunicate with each other NUMBER OF RINGS The number of rings can be set to 3 factory preset or 6 To change the number of rings proceed as follow Disconnect the power supply from the syst...

Page 9: ...N of the door station to switch on b If the door station uses the Art 4303N plus the Art 4330N pressing this button during a conversation switches the video signal coming from the camera module to the video signal coming from the camera module input for external camera c Activate bus relay board Art 2305 push button To activate a bus relay pick up the handset and press as many times as the address...

Page 10: ...8 hours ON No privacy time expiration the privacy service is enabled or disabled only by the pri vacy button SW3 INTERCOMMUNICATION SETTINGS Switches Status 4 3 2 1 Intercommunication Mode switch 1 Videophone Extension switches 2 3 OFF OFF 1 Master OFF ON 2 Slave ON OFF 3 Slave ON ON OFF Intercommunication between videophones in the same apartment To call an exten sion pick up the handset then pre...

Page 11: ...s carried out by the dip switches located on the rear of the videophone Controls Call tone volume contrast and brightness Power Supply Supplied by the BUS line Working Temperature 10 50 ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www videx security com Tech Line...

Page 12: ...tton for more than 3 seconds will switch the videomonitor into SIMPLEX speech mode Press and hold the button to speak to the caller LED 2 will flash rapidly release the button to listen LED 2 will flash slowly If the but ton is not pressed for 10 seconds the videomonitor will switch off The videomonitor will revert to duplex speech when another call is made When pressed shorts terminal S2 to Termi...

Page 13: ...e required melody Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Notes The second melody increases its volume at each ring first ring starts at minimum volume level up to the maximum volume level on the last ring Are available 4 levels of volume if are set 6 rings the fourth the fifth and the sixth will be emitted at the maximum...

Page 14: ... must be supplied locally using a power supply Art 2321 and connecting respectively BUS to terminal 14 and BUS to terminal 11 of the pcb connection board provided with the Art 5980 PRIVACY UNLIMITED SW2 1 If this switch is set to OFF default the privacy duration is defined by switches 2 and 3 If this switch is set to ON the privacy duration is unlimited and the service can be enabled or disabled o...

Page 15: ... Fig 4 and push down as suggested by the pointers in Fig 3 the videophone will lock into place To remove the videophone hold it firmly and push the unit in an upward direction until the videophone h unlocks from the mounting plate c SPECIFICATION Housing Mounting 5000 Series Videophones mounting plate plus connection board Push buttons Yes 6 Programming Yes carried out by the dip switches located ...

Page 16: ...ercom will revert to duplex speech when another call is made Privacy on off button If the unit is switched on press and keep pressed this button for more than 3 seconds to enable disable the service The relative LED will illuminate when the privacy service is enabled If the unit is switched off keep this button pressed together with the speak button until the privacy LED switches ON Intercommunica...

Page 17: ...is played Once the required melody is reached Wait approx 10 seconds for LED 1 to stop flashing to signal that the new value is stored and program mode has exited Notes The second melody increases its volume at each ring first ring starts at minimum volume level and adjusts up to the maximum volume level on the last ring There are 4 volume levels Rings after this will all play at full volume INTER...

Page 18: ...osition only for the last unit in the chain while on all other units must be set to B position bus termination disabled In case of units of different type video phones video monitor hands free or standard intercoms etc remains fixed the rule that the bus termination must be enabled only on the last unit in or der of connection INTERCOM CONNECTION BOARD A B JP1 1 2 3 4 5 6 7 8 9 10 Fig 2 SIGNAL ON ...

Page 19: ...e g to the top of the back plate as shown by pointer A in Figure 6 Move the lower side of the front plate g towards the back plate h and press until the unit locks into the back plate of the intercom To open the intercom once installed firmly grasp the bottom sides of the front plate cover pull forward in an upward direction to separate the front cover from the back plate as in Figure 6 NB Please ...

Page 20: ... 3 Move to close when BUS OUT 3 is not used B4 Close Open bus output jumper for BUS OUT 4 Move to close when BUS OUT 4 is not used BL Close Open bus through output jumper If the distributor is the last in line move to close otherwise leave open AMPLIFICATION Set the required level of amplification choosing between low medium and high SPECIFICATION Housing Mounting Plastic box 70x110x30mm direct wa...

Page 21: ...o close otherwise leave open SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push Buttons N A Programming N A Controls N A Power Supply Supplied by the BUS line Working Temperature 10 50ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www v...

Page 22: ...gnal amplification 3 levels high medium and low SPECIFICATION Housing Mounting Plastic box 50x60x20mm direct wall mounting Push Buttons N A Programming N A Controls Video signal amplification 3 levels Power Supply Requires local 2321 PSU Working Temperature 10 50ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 ...

Page 23: ...nect ing the BUS output of the first exchanger to the AUX of the second BUS with AUX and BUS with AUX IN1 Door station input 1 the signal may be amplified by the relative jumper L Low M Medium and H High IN2 Door station input 2 the signal may be amplified by the relative jumper L Low M Medium and H High IN3 Door station input 3 the signal may be amplified by the relative jumper L Low M Medium and...

Page 24: ...ON 32 seconds Switch 7 is not used For example if switch 1 is set to ON and switch 2 is set to OFF addresses 3 4 pressing the dot button on the intercom or double dot on the vid eophone 3 times will operate relay one while pressing 4 times will operate relay two EXTENSION SOUNDER RELAY SWITCH 8 ON When the unit is set in this mode switches from 1 to 7 8 is not used but set to on are used to set th...

Page 25: ...hes Status Binary Code Decimal Value 7 6 5 4 3 2 1 64 32 16 8 4 2 1 Decimal Code OFF OFF OFF OFF OFF OFF ON 0 0 0 0 0 0 1 1 OFF OFF OFF OFF OFF ON OFF 0 0 0 0 0 1 0 2 OFF OFF OFF OFF OFF ON ON 0 0 0 0 0 1 1 3 OFF OFF OFF OFF ON OFF OFF 0 0 0 0 1 0 0 4 OFF ON OFF OFF ON OFF ON 0 1 0 0 1 0 1 37 ON ON OFF OFF OFF ON ON 1 1 0 0 0 1 1 99 The table above shows how to set the address of the device Consid...

Page 26: ... active 0V the relay with address 1 of the Art 2305 if installed in the system will activate 12Vout 12Vdc Output With SW2 4 OFF it works as an open collector output that signals the privacy service status Internal link to ground when the privacy service is active Priv With SW2 5 ON required setting when the Art 2380 is in a parallel same address connection with other devices it must be linked to t...

Page 27: ... the retaining screws Fix the power supply to a DIN bar or directly to the wall using two expansion type screws Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams Check the connections and secure the wires into the terminals Replace the terminal covers and fix them using the relevant screws When all connections are mad...

Page 28: ...Controls N A Power Supply Supplied by the BUS line Working Temperature 10 50ºC CUSTOMER SUPPORT INFORMATION All Countries Customers UK Customers VIDEX Electronics S p A www videx it technical videx it Tel 39 0734 631669 Fax 39 0734 632475 VIDEX Security LTD www videx security com Tech Line 0191 224 3174 Fax 0191 224 1559 The product is CE marked demonstrating its conformity and is for distribution...

Page 29: ... to electro magnetic interference that may cause noises on audio video and lost of functionality over digital communications In case of use of cables not in conformity with above specification it is possible to experience deterioration of digital and video signals We suggest to use twisted cables with maximum resistance of 10 Ohm 100m for each wire between the farthest door station and the farthes...

Page 30: ...PrtCode ESVK_ENG_1 6 doc Pag 30 44 25 11 2009 Rev 1 6 ESVK 1 ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Page 31: ...PrtCode ESVK_ENG_1 6 doc Pag 31 44 25 11 2009 Rev 1 6 CESVK 1 ECLIPSE ONE WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Page 32: ...PrtCode ESVK_ENG_1 6 doc Pag 32 44 25 11 2009 Rev 1 6 ESVK 2 TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Page 33: ...PrtCode ESVK_ENG_1 6 doc Pag 33 44 25 11 2009 Rev 1 6 CESVK 2 ECLIPSE TWO WAY TWO WIRE VIDEO DOOR ENTRY KIT ...

Page 34: ...PrtCode ESVK_ENG_1 6 doc Pag 34 44 25 11 2009 Rev 1 6 CESVK ESVK 1 WITH VIDEO DISTRIBUTORS ART 318 317 BUTTON EXPANSION MODULE ART 125 AND ADDITIONAL VIDEOPHONES ...

Page 35: ...PrtCode ESVK_ENG_1 6 doc Pag 35 44 25 11 2009 Rev 1 6 CESVK ESVK 2 WITH ADDITIONAL DOOR STATION AND ENTRANCES EXCHANGER TWO ENTRANCES SYSTEM ...

Page 36: ...PrtCode ESVK_ENG_1 6 doc Pag 36 44 25 11 2009 Rev 1 6 ESVK 1 WITH 3 ADDITIONAL VIDEOPHONES AND RELATIVE POWER SUPPLIES ALL MONITORS SWITCHED ON DURING THE CALL ...

Page 37: ...PrtCode ESVK_ENG_1 6 doc Pag 37 44 25 11 2009 Rev 1 6 CESVK ESVK 1 WITH ADDITIONAL INTERCOM ...

Page 38: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL INTERCOM ...

Page 39: ...ESVK 1 1S WITH ADDITIONAL VIDEOPHONE ...

Page 40: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL VIDEOMONITOR ...

Page 41: ...ESVK 1 1S PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK ...

Page 42: ...CESVK 1 1S ECLIPSE PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK ...

Page 43: ......

Page 44: ...rity com e mail info videx security com Northern UK office VIDEX SECURITY LTD Unit 4 7 Chillingham Industrial Estate Chapman Street NEWCASTLE UPON TYNE NE6 2XX Phone 44 0870 3001240 Tech Line 44 0191 224 3174 Fax 44 0191 224 1559 Greece office VIDEX HELLAS Electronics 48 Filolaou Str 11633 Athens Phone 30 210 7521028 7521998 Fax 30 210 7560712 www videx gr e mail videx videx gr Danish office VIDEX...

Reviews: