EXTENSION NO – SW3.2..3
If the intercommunication between apartments is enabled (switch 1 of SW3 = ON) leave these two switches in default position (both to OFF). Otherwise,
if the intercommunication is between the same apartment (switch 1 of SW3 = OFF), set the extension addresses starting always from 1. During the ex-
ternal call, all video monitors in the same flat will ring but the video will be shown only from the videmononitor with extension address 1.
2 3 Extension
No.
OFF OFF 1
(default,
master)
ON OFF 2
(slave)
OFF ON 3
(slave)
ON ON 4
(slave)
SLAVE MODE - SW3.4
This set up concerns the answering mode of the video monitor when there is more than one unit (max 4) in the
same apartment. OFF (default) = during a call, only the video monitor with extension 1 (master) will show the
video. ON = the video monitor will be switched on independently of the extension address: in this case the
video monitor must be supplied locally using a power supply Art.2321 and connecting respectively BUS+ to
terminal 14 and BUS- to terminal 11 of the pcb connection board provided with the Art.5980.
PRIVACY UNLIMITED – SW2.1
If this switch is set to OFF (default), the privacy duration is defined by switches 2 and 3.If this switch is set to
ON, the privacy duration is unlimited and the service can be enabled or disabled only by the privacy button.
PRIVACY DURATION – SW2.2..3
This set up requires that switch 1 is set to OFF.
2 3
Duration
OFF OFF 15
minutes
ON OFF 1
hour
OFF ON 4
hours
ON ON 8
hours
VIDEOMONITOR CONNECTION BOARD ART.5980
Fig.3
SIGNAL ON CONNECTION TERMINALS
Terminal Signal
Description
1 GND
Ground
2 BUS1
Bus input
3
4 BUS2
Bus input
5 S1
Terminal controlled by the
S1
button, close to
GND
until the button is pressed
6 LED
Auxiliary LED power supply input (12Vdc)
7 S2
Terminal controlled by the
S2
button, close to
GND
until the button is pressed
8 GND
Ground
9 GND
Ground
10 LB
Local bell input (active low)
11 GND
Ground
12
13
14 +VAUX
Auxiliary power supply input (to be used when the switch 4 of SW3 is set to ON)
15
16
17
18 AL
Alarm input (not implemented yet)
19
20
Summary of Contents for 2 Wire
Page 1: ...Edition 2009 Rev 1 6 ...
Page 2: ......
Page 37: ...PrtCode ESVK_ENG_1 6 doc Pag 37 44 25 11 2009 Rev 1 6 CESVK ESVK 1 WITH ADDITIONAL INTERCOM ...
Page 38: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL INTERCOM ...
Page 39: ...ESVK 1 1S WITH ADDITIONAL VIDEOPHONE ...
Page 40: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL VIDEOMONITOR ...
Page 41: ...ESVK 1 1S PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK ...
Page 43: ......