Art.2380
Interface “2 Wire” to “4+1” audio system
Fig.1
Fig.2
DESCRIPTION
Interface to connect 4+ 1 audio devices to the VX2300 “2 Wire” Bus (For example the Art380 telephone interface or the Art275 PABX interface) Using
the items listed above (380, 275) it is possible to use a conventional household telephone as a standard intercom.
The operating mode of the telephone depends on the connected device and on the connections made, refer to the instructions of the Art.380 or Art275.
DIP-SWITCHES AND JUMPERS (FIG.1)
SW1
Switches from 1 to 7 are used for unit address (from 1 to 127 binary coded). Last switch (8) is not used
SW2
Switches 1,2 and 3 are used to set privacy duration time. Switch 4 is used to set the “Priv” signal operating mode
SW3
Switches 1,2 and 3 are used for intercommunication settings. Switch 4 is not used
S1
Impedance terminator. The jumper must be normally closed. When more videophones/intercoms are connected in parallel (from a pe-
ripheral to another and so on until the last) the jumper must be open for all the intercoms except for the last following the order of connec-
tion.
PROGRAMMING
After each programming operation carried out through dip-switches or jumpers it is necessary to temporary disconnect the device from the BUS or from
the power supply if locally powered.
SW1 – DEVICE ADDRESS
Switches Status
Binary Code – Decimal Value
7 6 5 4 3 2 1
64 32 16 8 4 2 1
Decimal
Code
OFF
OFF
OFF
OFF
OFF
OFF
ON
0 0 0 0 0 0 1 1
OFF
OFF
OFF
OFF
OFF
ON
OFF
0 0 0 0 0 1 0 2
OFF
OFF
OFF
OFF
OFF
ON
ON
0 0 0 0 0 1 1 3
OFF OFF OFF OFF ON OFF OFF 0
0
0
0
1
0
0
4
OFF
ON
OFF
OFF
ON
OFF
ON
0 1 0 0 1 0 1 37
ON
ON
OFF
OFF
OFF
ON
ON
1 1 0 0 0 1 1 99
The table above shows how to set the address of the device. Considering that ON = 1 and OFF = 0, multiply each digit for the relevant decimal weight
then sum the values obtained to get the address: E.g. as highlighted in the table OFF,ON,OFF,OFF,ON, OFF,ON in binary is equal to 0100101 then
multiplying each digit for the relevant decimal weight you obtain the address that is 37.
Note
The maximum number of units allowed is 100 but the address of each unit can be a value between 1 and 127.
SW2 – PRIVACY DURATION TIME
Switches Status
Privacy Mode
(switch 1)
Privacy Duration
(switches 2,3)
4 3 2 1
OFF OFF
15 minutes
OFF ON
1 hour
ON OFF
4 hours
ON ON
OFF
The privacy duration time is set by switches 2 and 3. After the privacy service is en-
abled, it is disable when the set time expires or the relevant button is pressed again.
8 hours
ON
No privacy time expiration: the privacy service is enabled or disabled only by the
relevant button.
OFF
The “Priv” terminal works as an open collector output to signal the status of the privacy service. When the service is enabled the “Priv”
output shorts to ground.
ON
This mode must be set when the Art.2380 is connected in parallel (with the same address) to one or more inter-
coms/videophones. Make a link between terminals “Priv” and “2”.
Summary of Contents for 2 Wire
Page 1: ...Edition 2009 Rev 1 6 ...
Page 2: ......
Page 37: ...PrtCode ESVK_ENG_1 6 doc Pag 37 44 25 11 2009 Rev 1 6 CESVK ESVK 1 WITH ADDITIONAL INTERCOM ...
Page 38: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL INTERCOM ...
Page 39: ...ESVK 1 1S WITH ADDITIONAL VIDEOPHONE ...
Page 40: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL VIDEOMONITOR ...
Page 41: ...ESVK 1 1S PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK ...
Page 43: ......