Two Wire Videokit ESVK Series
PrtCode:ESVK_ENG_1.6.doc – Pag.16/44
25/11/2009
Rev.1.6
Art.5188
Hands Free Intercom for VX2300
164,00
74,00
23,50
24,50
1 2 3 4 5 6 7 8
ON
SW1
12
3
4
ON
SW3
A
B
JP1
2
1
4
3
Fig.1
DESCRIPTION
PUSH BUTTONS, LEDS AND CONTROLS (FIG.1)
Bus Relay Button to Activate bus relay board Art.2305. To activate a bus relay press as many times as the address value of the relay.
Answer button - On an incoming call, operation of this button allows the user to answer and converse with the visitor. LED 2 will illumi-
nate.
Camera recall button - Press as many times as the DEVICE N. of the door station to switch on.
Switch off button - With the system switched on, momentary operation of the button will switch the unit off. The intercom will also auto-
matically switch off after a time delay if the button is not pressed. LED 2 will switch off.
Simplex button - Pressing and holding the button for more than 3 seconds will switch the intercom into SIMPLEX speech mode. Press
and hold the button to speak to the caller (LED 2 will flash rapidly), release the button to listen (LED 2 will flash slowly). If the button is
not pressed for 10 seconds the intercom will switch off. The intercom will revert to duplex speech when another call is made.
Privacy on-off button:
−
If the unit is switched on, press and keep pressed this button for more than 3 seconds to enable/disable the service. The relative LED
will illuminate when the privacy service is enabled.
−
If the unit is switched off, keep this button pressed together with the “speak” button
until the privacy LED switches ON.
Intercommunicating call button - For an intercommunicating call, when the intercom is in stand-by, press as many times as the extension
or address value to call.
Door open button - During a call, operation of this button will activate the “door open” relay (NO1, NC1, COM1). LED 4 will illuminate if
terminal 6 has been connected to a door contact.
1
Programming LED
2
LED relating to the operation of the answer/switch off/camera recall/simplex button
3
LED relating to the operation of privacy button
4
LED relating to the operation of door open button(powered from the connection terminal “2” & GND "1" on the connection board)
Loudspeaker volume control
Call tone volume control
PROGRAMMING
The intercom setup consists of the following settings:
-
Number of Rings;
-
Privacy duration;
-
Melody selection;
-
Unit address (1..127, switches 1 to 7 of SW1);
-
Intercommunication mode (between apartments or within apartment switch 1 of SW3);
-
Extension address (1..4, switches 2,3 of SW3);
-
Bus Termination (JP1 jumper on connection board);
Summary of Contents for 2 Wire
Page 1: ...Edition 2009 Rev 1 6 ...
Page 2: ......
Page 37: ...PrtCode ESVK_ENG_1 6 doc Pag 37 44 25 11 2009 Rev 1 6 CESVK ESVK 1 WITH ADDITIONAL INTERCOM ...
Page 38: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL INTERCOM ...
Page 39: ...ESVK 1 1S WITH ADDITIONAL VIDEOPHONE ...
Page 40: ...CESVK 1 1S ECLIPSE WITH ADDITIONAL VIDEOMONITOR ...
Page 41: ...ESVK 1 1S PLUS CODELOCK ART 4800 AND ART 2322 TO PROVIDE POWER SUPPLY TO THE CODELOCK ...
Page 43: ......