background image

25H/SP/DDA/2W - TECHNICAL MANUAL

EN-UK - V.1.2 - 04/01/16

39

VIDEX

25H/SP/DDA/2W

 (1 way “2 wire” DDA audio intercom kit)

Summary of Contents for 11J/SP/DDA/2

Page 1: ...W 1 Way 2 Wire DDA Audio Intercom Kit Technical Manual 25H SP DDA 2W EN UK V 1 2 04 01 16 WE RECOMMEND This equipment is installed by a Competent Electrician Security or Communications Engineer CALL SPEAK BUSY OPEN VIDEX ...

Page 2: ...marking indicates that the product respects the requirements of the applicable European Community Directives in force specifically EMC 2004 108 ECC LVD 2006 95 ECC and CE MARKING 93 68 ECC CE marking is appliedbythemanufacturer orpartydelegatedtodosobythemanufacturer under their own responsibility It was created to eliminate obstacles to the circulation of products in European Union Member States ...

Page 3: ...71 AUDIOPHONE 13 ART 521 POWER SUPPLY 14 SOFTWARE INSTALLATION AND SETUP 15 THE MAIN PROGRAMMER SCREEN 16 24 THE STATUS AND PROGRESS BAR 24 25 CABLE REQUIREMENTS 26 BLOCK CABLE DIAGRAM 27 WIRING DIAGRAM 28 LOCK RELEASE WIRING AND BACK EMF PROTECTION 29 CONNECTION TO MAINS SAFETY AND GUIDANCE NOTES 29 30 POWER SUPPLY INSTALLATION 30 31 PANELANDBACKBOXINSTALLATION 31 33 PANEL CARE AND MAINTENANCE 34...

Page 4: ...more user friendly helping comply with the Equality Act 2010 The intercom panel is manufactured from 12 gauge 316 grade vertically brushed stainless steel and incorporates a speak busy and door open call progress LEDs An additional feature is the 2 line 16 digit display which also includes speech annunciation and is used to indicate the progress of a call It also has a user friendly DDA compliant ...

Page 5: ... 50mm 157mm 60mm 124mm 80mm 280mm 260mm 50mm 317mm 284mm 60mm 123mm INTERCOM BACK BOXES The DDA audio kit comes with a standard flush back box VRFB120x280 A flush back box with bezel VRBB120x280 and a surface back box with rainshield VRSB120x280 shown below are also available on request Back Box Dimensions FRONT PANEL FLUSH VRFB120x280 FLUSH WITH BEZEL VRBB120x280 SURFACE WITH RAINSHIELD VRSB120x2...

Page 6: ...X 25H SP DDA 2W 1 way 2 wire DDA audio intercom kit CALL SPEAK BUSY OPEN Art UIM 138 User information module Made in Italy USB 0VA0 I1 I2 I3 I4 I5 Up Down High Low 1 2 3 4 5 6 7 8 ON 120mm 280mm 1 2 3 7 8 9 10 11 12 13 14 18 16 17 15 4 6 5 INTERCOM DOOR PANEL ...

Page 7: ...phone cable SYSTEM OPERATION In standby the door panel s display will show PRESS BUTTON TO CALL the call button will be illuminated and waiting to be pressed Upon pressing the button a reassurance tone will be heard at the door panel the busy LED on the panel will switch ON and the display will show CALLING as the panel announces that it is calling the audiophone The audiophone will ring Once the ...

Page 8: ...h button pre wired into the J1 and J2 button harness using the yellow 1 and white A wires The amplifier can be configured as a MASTER or a SLAVE panel depending on the number of Art 138N amplifiers connected on a system this can be done by adjusting switch 1 on the 8 way dip switch The default setting is MASTER switch 1 in the ON position Dip Switch Settings DSW1 Switches 2 and 3 on the Art 138N c...

Page 9: ...o the required levels microphone volume adjustment speaker volume adjustment balance control for microphone and speaker switch 6 OFF switch 7 OFF switch 8 OFF device 1 switch 6 ON switch 7 OFF switch 8 OFF device 2 switch 6 OFF switch 7 ON switch 8 OFF device 3 switch 6 ON switch 7 ON switch 8 OFF device 4 switch 6 OFF switch 7 OFF switch 8 ON device 5 switch 6 ON switch 7 OFF switch 8 ON device 6...

Page 10: ...ggered will activate the door open relay SL Active low output active during a call BS Busy signal active low input output during a call L BUS line data input BUS line ground input 12 12Vdc power supply input GND Power supply ground input J1 Pins A D button matrix column terminals button commons J2 Pins 1 6 button matrix row terminals J3 UIM harness connection for connection of UIM 138 display modu...

Page 11: ... to be programmed The module connects to the 138N amplifier module via a plug in wire harness and connects to a PC or laptop via a standard USB connection Key Features Include 2 line 16 character blue back lit display Voice annunciation output 5 programmable auxiliary inputs A switched 0V auxiliary output USB port Display contrast and voice annunciation volume adjustments Display Contrast and Voic...

Page 12: ...iary output triggered for auxiliary output time at beginning of call 4 10 currently unavailable left for future expansion Art UIM 138 Display Module Dimensions Terminal Connections Connection Description 0V 0V ground input AO Programmable auxiliary output this is an open collector output switched 0V Please refer to the table above for full list of programmable output modes I1 I5 5 programmable aux...

Page 13: ...ted pair telephone cable is recommended and for external use a CW1128 twisted pair telephone cable is recommended Audiophone Dip Switch Settings Internally the Art 3171 audiophone has an 8 way dip switch to set up the phone ID and is based on binary addressing for the 25H SP DDA 2W audio kit the default address for the Art 3171 audiophone should be set to phone ID 1 as shown below Dip Switch No 1 ...

Page 14: ... always be used with this type of power supply It is contained in a standard 9 module A type DIN box for mounting on a standard DIN rail IMPORTANT NOTE The 230Vac mains input terminals on this PSU should be connected to the mains supply via a fused spur or preferably an all pole circuit breaker refer to pages 29 30 Art 521 Dimensions Terminal Connections Terminal Function 13 5Vdc output 800mA cont...

Page 15: ...the right At the top of the window the software will show that it is checking for any devices connected to the PC or laptop SOFTWARE INSTALLATION AND SETUP Launching the Software Fig 1 After the USB driver has been installed ensure that the UIM 138 is connected to the 138N speaker amp using the plug in wire harness and any necessary auxiliary inputs outputs are connected this will depend on the us...

Page 16: ...ab the following fields can be edited Main Display Logo the main logo text can be entered into each field line The information entered into these fields will be the main logo shown on the UIM 138 display Switch Display Logo the switch logo text can be entered into each field line The information entered into these fields will alternate between the main display logo approximately every 5 seconds Au...

Page 17: ...ield under the apartments tab refer to page 19 4 Call ID 25 when set into mode 4 the UIM 138 will trigger the 138N speaker amp to call phone ID 25 Aux 2 Mode the following modes can be set and will be active when auxiliary input I2 is triggered 1 Aux 2 Message when set into mode 1 the text entered into the Aux 2 display text fields will be shown on the UIM 138 display 2 Activate AO when set into m...

Page 18: ...trigger the 138N speaker amp to end the call made to a flat 4 Call ID 29 when set into mode 4 the UIM 138 will trigger the 138N speaker amp to call phone ID 29 Aux Out Mode AO by clicking on the drop down menu button q on the right of the field the required auxiliary output mode can be set refer to the table on page 12 The following modes can be set 1 MODE 1 Aux Out triggered by auxiliary input I2...

Page 19: ...will only be applicable on multiple entrance systems where an Art 2206N bus exchange device has been used Access Code this field is not used Name the name of the user or the apartment or office name can be entered into this field and will be available to select if the scroll and call modes described on page 17 have been setup on auxliliary inputs I1 I2 and I3 on the UIM 138 display The information...

Page 20: ...t u Select this option from the drop down menu and a list of the most recent database files that were previously accessed will be shown To open select and click on the relevent file required and the settings and apartment tabs will show the saved database information Save select this option from the drop down menu to save the database file that is open Save As select this option from the drop down...

Page 21: ...nction From the top menu on the main programmer screen when System is selected the following drop down menu will appear as shown There are four options shown on the drop down list however the UIM 138 option will already be ticked The other three options will not be applicable this is because when the programmer software first loads up it will automatically detect that a UIM 138 display module is c...

Page 22: ...ing the UIM 138 display module Simply click on the start button to upload or the cancel button to exit out of this option Please note that when uploading the display will show please wait and a progress bar will be shown on the second line of the display once complete it will then display OK and then revert to the new message Upload Only Blocks select this option from the drop down menu to upload ...

Page 23: ... drop down file menu the print out will also show this list in alphabetical order By Apartment No selecting this option from the drop down menu will arrange the list of programmed apartments in the apartments window in numerical order as shown on the right if a print out is selected from the drop down file menu the print out will also show this list in numerical order From the top menu on the main...

Page 24: ...he COM port connection between the programmer software and the UIM 138 display module Manually Connect although shown in the drop down list this option is not applicable The baud rate 9600 will already be selected and all options greyed out When the programmer software first loads up it will automatically check through the COM ports searching under different baud rates to see if the UIM 138 displa...

Page 25: ... successfully opened a saved file using the Open or Open Recent option from the File drop down list The status will update to the right of the progress bar as shown below Saved File this status is shown when the programmer software has successfully saved an open file using the Save or Save As option from the File drop down list The status will update to the right of the progress bar as shown below...

Page 26: ... 2 core YY 0 75mm 1 Please Note It is perfectly acceptable to use an equivalent cable type if a 2 core YY cable is not being used providing it meets the same cable characteristics as those described above and those shown in table A Art 3171 Audiophone Connections The Art 3171 audiophone requires a 2 core databus connection L and with a maximum acceptable resistance of 7 5Ω ohms or less For the dat...

Page 27: ...Release 25H SP DDA 2W Intercom Door Panel 20m 30m max PRESS TO RELEASE EMERGENCY DOOR RELEASE BREAK GLASS PRESS HERE ART 521 POWER SUPPLY Made in EEC PRI OUT 230V 12VDC 1A 50 60Hz 230V 0 Mains VIDEX BLOCK CABLE DIAGRAM Fig 2 below shows the minimum number of cable cores required for a 1 entrance 25H SP DDA 2W audio kit using the information taken from the tables shown on page 26 Fig 2 ...

Page 28: ...t Art UIM 138 User information module Made in Italy USB 0VA0 I1 I2 I3 I4 I5 Up Down High Low 1 2 3 4 5 6 7 8 ON PRESS TO RELEASE NC NO CO NC NO CO EMERGENCY DOOR RELEASE BREAK GLASS PRESS HERE INTERCOM DOOR PANEL Art 3171 Audiophone 12Vdc Fail Safe Lock Release CENTRAL CONTROL EQUIPMENT 1N4002 DIODE pre wired 1 2 3 4 5 6 7 8 ON Phone ID 1 1 2 3 4 5 6 7 8 ON Switch 1 set ON for MASTER The Art 521 p...

Page 29: ...flammable gases liquids or vapours Possible obstructions which would prevent or hinder the access and or removal of the Videx product Videx recommends that any cabling andVidex product be installed by a competent and qualified electrician security installation speclialist or communications engineer The system MUST be installed in accordance with the current I E E regulations in particular I E E Wi...

Page 30: ... Fig 4D or directly to the wall using two rawl plugs and two expansion type screws refer to Fig 4E Switch OFF the mains using the circuit breaker mentioned previously on page 29 and then make the connections as shown on the installation diagrams Check the connections and secure the wires into the terminals ensuring that the low voltage signal cables are routed separately from the high voltage main...

Page 31: ...ack box front is flush with the wall surface Always ensure the panel is tightened sufficiently to compress the neoprene seal In the event of gaps due to uneven walls we suggest a silicon sealant be used In the event of water ingress to the back box we would also suggest drilling 3x4mm holes at the bottom of the back box to allow any collection of water to escape Always ensure all cable entry point...

Page 32: ...25H SP DDA 2W TECHNICAL MANUAL EN UK V 1 2 04 01 16 32 VIDEX 25H SP DDA 2W 1 way 2 wire DDA audio intercom kit Fig 5 Fig 6 Fig 7 Flush VRFB120x280 Bezel VRBB120x280 Surface VRSB120x280 ...

Page 33: ...wever consideration should be taken into account to mount the back box based on user specific requirements The intercom cables can be fed through any of the available 20mm knockouts at the rear of the back box and should be given enough slack to enable the cable wires to be connected to the panel components VR Panel Mounting After the back box has been fitted the VR panel can then be fixed into po...

Page 34: ...a household polish Routine Cleaning Soap detergent or dilute 1 ammonia solution in warm water Staining and discolouration Mild non scratching creams and polishes Take care to avoid build up of creams in the buttons which could cause sticking Cleaners that CANNOT be used Chloride containing cleaners Hydrochloric acid based cleaners Sidol stainless steel cleaner can affect engraving Hydrochloride bl...

Page 35: ...the bottom line of the display as shown in Fig 13 7 Once the display shows OK as shown in Fig 14 remove the link between 0V and I5 The settings in the UIM 138 display module will be returned back to factory default VIDEX UIM 138 R 1 0 138N 1 3 PLEASE WAIT OK QUICK USB DRIVER SETUP GUIDE 1 Insert the 2X00PC software CD into the PCs CD DVD rom drive 2 Select RUN from the start menu 3 Type in D CDM20...

Page 36: ...l there is speech playback refer to page 9 Check that the volume and balance POTs on the back of the 138N speaker haven t been turned down Try adjusting the volume and balance POTs on the back of the 138N speaker amp until there is speech playback Checkthespeechplaybacksettinghasn tbeenswitchedoffviatheprogrammer software on the settings window refer to pages 16 17 The auxiliary inputs on the UIM ...

Page 37: ...e connected correctly to the DDA call button refer to page 8 The Intercom panel makes a call correctly and the audiophone rings but when answered the communication is cut OFF Check the L BUS voltage should be 7 5Vdc at the intercom panel and at the audiophone Increase the CSA of the L BUS connection by doubling up on the cable cores The call rings through to the audiophone okay but there is only o...

Page 38: ...25H SP DDA 2W TECHNICAL MANUAL EN UK V 1 2 04 01 16 38 VIDEX 25H SP DDA 2W 1 way 2 wire DDA audio intercom kit NOTES ...

Page 39: ...25H SP DDA 2W TECHNICAL MANUAL EN UK V 1 2 04 01 16 39 VIDEX 25H SP DDA 2W 1 way 2 wire DDA audio intercom kit ...

Page 40: ...TECHNICAL MANUAL EN UK V 1 2 04 01 16 Northern Office Videx Security Ltd Unit 4 7 Chillingham Industrial Estate Newcastle Upon Tyne NE6 2XX Southern Office Videx Security Ltd 1 Osprey Trinity Park Trinity Way London E4 8TD ...

Reviews: