Victoria-05 Ltd.
14
Interim Purge
There are 2 parameters to set in the Interim
Purge:
Period
This setting is about how long it will take the
fireplace to launch cumulate residue clean.
The time to set should be the sum of the
operation of the screw conveyor. This way one
can calculate the number of pellets after which
there should follow a cleaning process!
Fan 100%
How long an Interim Purge will last.
200 sec.
(100
÷
1000)
10 sec. (2
÷
100)
Restore all factory settings!
Outputs Test
(Manual Mode).
Activates all outputs at the same time
- Pump .Not uses.
- Heater
- Smoke Fan*
- Screw Conveyor
-Second fan(room fan)
* Keep in mind that in order to activate the smoke fan, the fan
rotation value must first be set in the grey field!
10.3. Outs test.
The test is necessary to check the working order and proper connection of electrical components in the pellet stove. The test of
the outputs is possible only in
ready mode
. When going into
starting mode
the test it terminated. To perform test is necessary
to go into
“output test”
menu and test all four components.
11.Instruction manual.
11.1.Wood pellets loading.
The capacity of the pellet fuel hopper is 24 kg. The opening for charging the hopper is with dimensions 167
х 300
mm.
If the hopper is left without pellets, the pellet stove will stop working and
„
Unsuccessful Ignition
“
alarm will be shown on the
display.
11.2.Wood pellet refuelling.
At the initial ignition of the pellet stove or at the ignition after the pellets in the hopper are exhausted, it is necessary
to manually fill the pellet auger, using the
Manual Filling
icon from the main screen.
It is possible that some pellets remain in the hopper. Vacuum clean the hopper monthly to avoid the accumulation of
waste and ash.
11.3.Starting up the system.
To start the Control Unit, one needs to hold the icon, showing the processes, for at least 3 seconds, which will produce a sound
signal to announce the system’s being started.
To stop the Control Unit, one needs to hold the icon, showing the processes, again for 3
seconds, which will transfer the device into Clean Mode and Ready Mode.
The first mode after Ready Mode is Start Mode. In this mode, what happens is the so called
initial clean, which lasts 60 seconds by default. The smoke fan is set on maximum speed to
clean the ashtray. If we would like, we can change the time for initial clean in the Clean
Menu.
Summary of Contents for VITTORIA 8
Page 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...
Page 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Page 20: ...Victoria 05 Ltd 20...
Page 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...
Page 22: ...Victoria 05 Ltd 22...