background image

Victoria-05 Ltd.

 

 

 

 

5.Control unit. 

The control unit is equipped with a system for monitoring and controlling of the burning process. It ensures higher efficiency, 
optimizes  the  fuel  consumption  and  minimizing  the  emissions.  With  sensors  for  the  pressure  in  the  fire  chamber  and 
temperature sensors at the flue outlet for the temperature of the flue gasses, the system  analyses the collected data from the 
burning and automatically controls it and optimizes it.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Picture.1. 

 
6.Components. 

Ignition

Performs the ignition of the pellets

 

Fume extractor

Extracts the flue gases from the combustion chamber to the flue pipe outlet and intakes combustion air by vacuum. 

Gear motor

Driven auger screw by means of which the pellets are conveyed from the pellet fuel hopper to the combustion chamber. 

Room air fan: 

Ensures additional circulation of the air in the room. 

Pressure Switch (Pressostat): 

Measures the vacuum in the combustion chamber. 

7.Operating mode. 

Pellet stove works with wood pellets. They are cylindrical granules, made of pressed wood, whose combustion is controlled by 
an electronic control system. 

The pellet fuel hopper, position (A) of Picture 2, is located at the rear of the pellet stove. Filling of the hopper is made through a 
hatch  located  in  the  rear  part  of  the  upper  top  of  the  pellet  stove.  The  pellets  are  transported  from  the  hopper  (A)  to  the 
combustion chamber (L) by means of a screw auger (B) driven by a gear motor (C). 

The initial ignition of the pellets is carried out by hot air, which is sucked in around the ignition (K) in the combustion chamber 
through the fume extractor (G). Fume extractor provides combustion air by sucking in from air inlet 

Ø

40 mm(D)by the room or 

by outside atmosphere. Upon submission of air from the room must have provided an influx of outside air. 

The flue gases are sucked from the combustion chamber through the fume extractor (G) and are conducted to flue socket 

Ø 

80 

mm (F). 

Summary of Contents for VITTORIA 8

Page 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...

Page 2: ...ONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 13 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 OUTS TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUELLIN...

Page 3: ...ailure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the fo...

Page 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Page 5: ...Alarm Exhaust gases Pressostat Connected to the combustion chamber It reads the values of the vacuum in the combustion chamber and compares it with the pressure in the room Temperature sensor of the...

Page 6: ...m Pressure Switch Pressostat Measures the vacuum in the combustion chamber 7 Operating mode Pellet stove works with wood pellets They are cylindrical granules made of pressed wood whose combustion is...

Page 7: ...rea Pellet stove is designed developed programmed and tested to operate with wood pellets class A1 according to EN plus and BDS EN ISO 17225 2 2014 with the following parameters Maximum diameter 6 mm...

Page 8: ...to ensure a sufficient supply of oxygen necessary for combustion Additionally it can be delivered outside air through a pipeline of 50 mm In this case it is possible to emerge condensate If necessary...

Page 9: ...llet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be cleaned with a soft brush or a dry cloth but in any case not with a d...

Page 10: ...utton a green bar appears at the bottom of the display Wait until it is full to execute the command Hiding the green bar means that the value is stored correctly The return icon is removed during the...

Page 11: ...le is connected 0 no module 1 a module is present but is not connected 2 a module is connected to the router Languages Here there is a Control Unit Language shortcut key The system offers four languag...

Page 12: ...e fireplace will stop The settings have been restricted in four access levels The first level is Installer The second level is Service Technician The third level is Delete Errors with a password 7777...

Page 13: ...ion can do among four display languages Bulgarian English Dutch and German 10 2 5 Service technician settings Types of settings for service technician entered with service technician password Paramete...

Page 14: ...pellets loading The capacity of the pellet fuel hopper is 24 kg The opening for charging the hopper is with dimensions 167 300 mm If the hopper is left without pellets the pellet stove will stop worki...

Page 15: ...in the end P1 Switching among these is based on the temperature pre set as room temperature If the room temperature is set to 30 in the Modulation 5 Menu the Thermal Difference one should set is 4 in...

Page 16: ...ve was not used for an extended period Clean the ignition 12 3 Seasonal maintenance performed by the installer The user has to contact the installer to perform the seasonal maintenance Disconnect the...

Page 17: ...cted alarm s activation on the right To delete the alarms on the right enter the password 7777 To delete the alarms on the left too enter the password again Pressure Switch Activated if insufficient v...

Page 18: ...an the flue gasses be sent out directly through the wall NO Removal must be in accordance with existing standards For proper operation of the pellet stove the chimney metal or masonry has to be comple...

Page 19: ...r 4 Ignition 18 Left side plate 5 Pressure switch 19 Right side plate 6 Controller set 20 Special tool 7 Display 21 Fume temperature sensor 8 Crossflow blower 22 Thermostat of the pellet fuel hopper 7...

Page 20: ...Victoria 05 Ltd 20...

Page 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...

Page 22: ...Victoria 05 Ltd 22...

Page 23: ...maining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following...

Page 24: ...for repairs under warranty Company Receipt date Type of repair Delivery date Carried out Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 e mail in...

Reviews: