background image

03.2021

 

 

 

INSTRUCTION MANUAL 

for installation and operation of pellet stove 

VITTORIA 8

 

 

 

3

 

 

1. Introduction. 

We congratulate you on the excellent choice! 

Do not leave this instruction manual unread. Installation and operation of a pellet stove associated with various legal 
obligations, which are explained in this instruction manual. According to the laws and regulations for safe use of 
appliances of this class, the purchaser and user of the pellet stove undertake using this instruction manual to inform 

themselves for the assembling and the right operation of the appliance. 

This instruction manual is provided to assist you and the team that will install, put into operation and service the pellet stove. 
Technicians, who will carry out the above activities to the pellet stove, must be trained and competent. 

Only adult persons familiar  with the instruction manual  should operate pellet  stove. Persons with limited  physical,  sensory or 
mental  abilities  or  lack  of  experience  and  knowledge  do  not  intend  pellet  stove  for  use,  unless  they  are  instructed  and 
supervised in the use of the appliance by a person responsible for their safety. 

The  pellet  stove  is  manufactured  and  tested  in  accordance  with  standards  EN14785,  EN60335-1,  EN60335-2-102,  EN55014-1, 
EN55014-2,  EN61000-3-2,  EN61000-3-3,  EN61000-4-2,  EN61000-4-4,  EN61000-4-5,  EN61000-4-11  and  meets  the  approved 
technical documentation 

Failure to follow the instructions described in this manual can lead to damage and consequences for which the manufacturer is 
not held responsible. 

 

2. Safety information. 

 

Pellet  stove  is  designed  to  heat  air  through  automated  burn  in  the  combustion  chamber  of  wood  pellets  with  a 

diameter of Ø 6 mm class A1.

 

 

Warranty is voided by unauthorized use of combustible material. 

 

The risk that could arise from non-compliance of this instruction manual is - direct contact with electric parts (internal), 

contact with fire or hot surfaces. 

 

Pellet  stove  is  equipped  with  safety  components  that  guarantee  automatically  locking  in  case  of  failure  of  any  of  its 

components. Safety components are activated without outside interference. 

 

Necessary  for  the  proper  operating  of  the  pellet  stove  is  its  proper  installation  in  accordance  with  the  following 

instructions. 

 

Fire door should not be opened during operation of the pellet stove. The burning process is automated and does not 

require external intervention. 

 

It is not allowed to burn the pellet stove if there are cracks in the glass. 

 

Under no circumstances there should not be allowed penetration of foreign substances in the firebox or hopper. 

 

Do not use combustible materials to clean soot in the chimney. 

 

Turn off the pellet stove from the electric supply before cleaning or servicing. 

 

Use a vacuum cleaner to clean the combustion chamber and pellet fuel hopper only when pellet stove is cold. 

 

Do not use water to clean the internal parts of the pellet stove. 

 

ATTENTION!

 During operation of the pellet stove there must not be allowed for a child to touch its surface, as it is hot. 

Danger of burning! 

 

The handle of the pellet stove warms as much as the front panel, so it must be operated with a heat-resistant glove. 

 

During operation of the pellet stove flue pipes and fire door are hot. 

 

Do not place flammable objects and liquids close to the pellet stove. 

 

NEVER

 use flammable liquids to ignite and burn the pellet stove. 

 

Do not obstruct fresh air to enter the room where pellet stove is installed and through the holes on the pellet stove. 

 

Do not soak pellet stove and do not touch electrical components with wet hands. 

 

Do not mount any adapters to flue pipes and chimney. 

 

To  operate  properly  and  safely,  pellet  stove  should  be  installed  in  a  room  that  is  fire-resistant  and  equipped  with 

everything needed (electricity, air exchange, vents). 

 

The temperature of the room where the pellet stove is installed must not be lower than 0˚C.

 

 

Rating label is placed on the back of the pellet stove. 

 

Keep  the  instruction  manual,  warranty  card  and  purchase  invoice  in  good  condition,  as  will  be  necessary  in  any 

inquiries. 

 

After extinction, do not burn the pellet stove again before cleaning the combustion chamber! 
Removed pellets from the combustion chamber should not be placed back in the pellet fuel hopper! 

 

 

 

Summary of Contents for VITTORIA 8

Page 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8...

Page 2: ...ONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 13 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 OUTS TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUELLIN...

Page 3: ...ailure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with the fo...

Page 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Page 5: ...Alarm Exhaust gases Pressostat Connected to the combustion chamber It reads the values of the vacuum in the combustion chamber and compares it with the pressure in the room Temperature sensor of the...

Page 6: ...m Pressure Switch Pressostat Measures the vacuum in the combustion chamber 7 Operating mode Pellet stove works with wood pellets They are cylindrical granules made of pressed wood whose combustion is...

Page 7: ...rea Pellet stove is designed developed programmed and tested to operate with wood pellets class A1 according to EN plus and BDS EN ISO 17225 2 2014 with the following parameters Maximum diameter 6 mm...

Page 8: ...to ensure a sufficient supply of oxygen necessary for combustion Additionally it can be delivered outside air through a pipeline of 50 mm In this case it is possible to emerge condensate If necessary...

Page 9: ...llet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be cleaned with a soft brush or a dry cloth but in any case not with a d...

Page 10: ...utton a green bar appears at the bottom of the display Wait until it is full to execute the command Hiding the green bar means that the value is stored correctly The return icon is removed during the...

Page 11: ...le is connected 0 no module 1 a module is present but is not connected 2 a module is connected to the router Languages Here there is a Control Unit Language shortcut key The system offers four languag...

Page 12: ...e fireplace will stop The settings have been restricted in four access levels The first level is Installer The second level is Service Technician The third level is Delete Errors with a password 7777...

Page 13: ...ion can do among four display languages Bulgarian English Dutch and German 10 2 5 Service technician settings Types of settings for service technician entered with service technician password Paramete...

Page 14: ...pellets loading The capacity of the pellet fuel hopper is 24 kg The opening for charging the hopper is with dimensions 167 300 mm If the hopper is left without pellets the pellet stove will stop worki...

Page 15: ...in the end P1 Switching among these is based on the temperature pre set as room temperature If the room temperature is set to 30 in the Modulation 5 Menu the Thermal Difference one should set is 4 in...

Page 16: ...ve was not used for an extended period Clean the ignition 12 3 Seasonal maintenance performed by the installer The user has to contact the installer to perform the seasonal maintenance Disconnect the...

Page 17: ...cted alarm s activation on the right To delete the alarms on the right enter the password 7777 To delete the alarms on the left too enter the password again Pressure Switch Activated if insufficient v...

Page 18: ...an the flue gasses be sent out directly through the wall NO Removal must be in accordance with existing standards For proper operation of the pellet stove the chimney metal or masonry has to be comple...

Page 19: ...r 4 Ignition 18 Left side plate 5 Pressure switch 19 Right side plate 6 Controller set 20 Special tool 7 Display 21 Fume temperature sensor 8 Crossflow blower 22 Thermostat of the pellet fuel hopper 7...

Page 20: ...Victoria 05 Ltd 20...

Page 21: ...03 2021 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 21...

Page 22: ...Victoria 05 Ltd 22...

Page 23: ...maining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the following...

Page 24: ...for repairs under warranty Company Receipt date Type of repair Delivery date Carried out Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 e mail in...

Reviews: