Parameter Description VD530 Series Inverter User Manual
- 202 -
C0-32
Number of
Pulse per
Cycle
1~30000
1
◎
Refers to the material around a layer, the number of turns of the reel, generally used for wire.
C0-33
Number of
Computatio
n Cycles
Function
Selection
0: Frequncy
1: Switch
2: Encoder
0
◎
Total number of layers=total pulse number / number of cycles per lay * number of pulse per cylcle),
through the increment of the number of pulse to determine the coil diameter change.
C0-34
Linear
Velocity
Input
Source
0: AI1
1: AI2
2: AI3 (expansion card)
3: PULSE input
4: Communication setting
0
◎
C0-35
Maximum
Linear
Velocity of
System
0.1m/min~6000.0m/min
1000.0m/
min
◎
When Linear velocity input source is given by analog, 100% corresponding maximum linear velocity
of the system.
C0-36
Coil
Diameter
Calculation
the Lowest
Linear
Velocity
0.1m/min~6000.0m/min
200.0m/
min
○
Set starting to calculate the lowest speed of the coil diameter. When inverter detects that the lieaar
velocity is less than that value, the inverter stop the coil diameter calculation. Set the value correctly
can effectively prevent the calculation of the coil diameter when low speed has a large deviation.
Generaly set to the maximum linear velocity of more than 20%.
C0-37
Automatic
Detection
Selection of
Starved
Feeding
0: Disabled
1: Enabled
0
○
C0-38
Automatic
Detection
Minimum
Frequency
of Starved
Feeding
0.00Hz~F0-10
10.00Hz
○
C0-39
Automatic
Detection
Threshold
of Starved
Feeding
1mm~1000mm
10mm
○