![Vicruns VD530 Series User Manual Download Page 204](http://html1.mh-extra.com/html/vicruns/vd530-series/vd530-series_user-manual_1013438204.webp)
Parameter Description VD530 Series Inverter User Manual
- 200 -
C0-16
Initial
Winding
Diameter 1
(Diameter)
1mm~10000mm
100mm
○
C0-17
Initial Coil
Diameter 2
(Diameter)
1mm~10000mm
100mm
○
C0-18
Initial Coil
Diameter 3
(Diameter)
1mm~10000mm
100mm
○
C0-19
Initial Coil
Diameter
Selection
(Diameter)
0: Empty salver diameter
1: Initial coil diameter 1
2: Initial coil diameter 2
3: Initial coil diameter 3
4: DI terminal selection
0
○
Select the input channel of the initial coil diameter.
0~3: fixed coil diameter value.
4: the initial vaue of the coil diameter can determined by two multi function terminals. If select tow
terminal port to determine the value of the initial coil diameter. the DI3 terminal F5-03 is set to 54
( initial coil diameter/feed forward coefficient selection terminal 1), and the DI4 terminal F5-04 is set to
55 (initial coil diameter/feed forward coefficient selection terminal 2).
The initial coil diameter selection relationship is as follows:
DI4
DI3
Initial Coil Diameter Source
0
0
Determined by C0-15
0
1
Determined by C0-16
1
0
Determined by C0-17
1
1
Determined by C0-18
C0-20
Coil
Diameter
Filtering
Time
0.00~10.00s
1.00
○
The filtering time of coil diameter is calculated. If the the filtering time is increased, the interference
resistance will be enhanced, but the sensitivity will decrease.
C0-21
Minimum
Variation of
Roll
Diameter
1mm~1000mm
1mm
○
When the fluctuation range is higher than thatvalue, the adjustment is used to maintain the stability of
the coil diameter calculation, but the sensitivity will decrease.
C0-22
Coil
Diameter
Calculation
Delay
0.0s~60.0s
0.0s
◎
Delay the setting time, the system began to calculate the coil diameter.
Summary of Contents for VD530 Series
Page 2: ......
Page 9: ...VD530 Series Inverter User Manual Safety and Precautions 5 damage or performance reduce...
Page 230: ......