20
••••
Technical Information
XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control
OPERATIONAL
General:
Unit is operated using external devices (1 CPU and up to 10
I/O Devices). When set to intelligent mode (IDL), if one or
more Stations become corrupt (device locking, incorrect
wiring or excessive noise), the unit will shut down these
Stations and provide status indication on the front panel
LEDs. In addition, the CPU line will be monitored for status
and indication will be displayed accordingly with the front
panel LED.
Control Format:
RS-422 protocol data, full duplex operation at 4800, 9600 or
19200 baud.
MECHANICAL
Mounting:
Desk mount (bumpers provided) or Rack mount.
Dimensions:
Height:
1.7
in.
(43
mm).
Width:
19.0
in.
(483
mm).
Depth:
7.5
in.
(191
mm).
Weight:
6.5 lb (2.9 kg).
Construction:
Steel
chassis
and
cover.
Finish:
Black
baked
enamel
chassis
and
cover.
ENVIRONMENTAL
Operating Temperature Range:
32 to 122°F (0 to 50°C).
Operating Humidity Range:
Up
to
90%
relative,
noncondensing.
Storage Temperature Range:
-40
°
to 150
°
F (-40
°
to 65
°
C).
Storage Humidity Range:
Up
to
90%
relative,
noncondensing.
Figure 18
Front and Rear Panel Views