Cable Recommendations
RS-422 Protocol
For all RS-422 protocol connections terminated in open wires or onto D-shell type connector use a 2-
conductor (twisted pair) shielded copper wire to make the connections. Refer to Table 1, Shielded, Dual
Twisted-Pair Cable Maximum Operating Distances.
For all RS-422 protocol connections
terminated in RJ-45 type (8 conductor)
cable, use a cable that does not exceed
6 ft (15 m). For wire runs longer than
this, use RJ-45 Termination Boxes
locally and longer runs with shielded
twisted-pair-cables in accordance with
Table 1.
Manual References for Associated Equipment
CPUs
V1200X
V1200X
Series
Transmitter/CPU
X379
V1300X
Microprocessor-Based
Control
System
X553
VPS328/V1422
VPS328/V1422 Digital Control, Installation/Operation
X826
Input Devices
V1300X-DVC/RVC
Intelligent Remote Control Panels
X777
V1400X-DVC
System
Console XX090
Output Devices
V1200R-LM
Multiple
Receiver
X512
V1301R Outdoor
Receiver
X506
V1311RB
Universal
Receiver
X871
V1319R Dual
Station
Receiver
X825
V15UVS Omniscan
Dome X806
V7UVS
Surveyor
Mini
Dome
X971
V5UVS
Surveyor
99
Dome
X978
SUR2000
Surveyor2000
Mini-Dome
XX031
CABLE TYPE
DISTANCE ft (m) max. NUMBER REQUIRED
Belden 9406
5000 (1500)
1
Belden 9402
5000 (1500)
1
Belden 8723
8000 (2400)
1
Belden 8162
15000 (4600)
1
Belden 9729
15000 (4600)
1
Belden 9182
25000 (7600)
2
Table 1
Shielded, Dual Twisted-Pair Cable
Maximum Operating Distances