17
3. After the width and height are set, press “AUX2” to save the
current width and height of the mask area.
4. After exiting the menu, in joystick PTZ operations, the set
mask area will not change along with the position and size
changes of the dome.
Notes:
1. The two privacy mask modes can not be enabled at the same
time.
2. The corner of the center for the mask area can not surpass 5
0
°.
4.6.2 ALARM SET
The dome provides 4 alarm inputs and 1 relay output. Each input
can be used to connect to an external alarm device such as door
contact, motion sensor or smoke alarm. The auxiliary relay can be
set to respond to the alarm input.
By programming the ALARM SET menu, you can define the input
status and assign it with an action (a preset), so that when the
normal state changes to abnormal, the dome will automatically
position at the preset for surveillance.
ALARM ENABLE
Function:
Enable/disable the alarm. Default: OFF.
ALARM-IN NO.
Function:
Set the alarm input number. 1
~
4 options.
ACTIVE INPUT STATUS
Function:
Select Low/High.
SET ACTION
Function:
Assign each alarm input with a preset to call upon
alarm.
Options:
NONE -
Indicates a no-action command that disables
the automatic preset call (default).
PRESET 001 ~ PRESET 032 -
Select one of the 32
presets for automatic call up.
AUTOPAN/AUTO TOUR 001~ 004:
Choose one of the
autopan/auto tours as the dome's alarm action.
NORMAL TOUR 001~ 004: AUX ON/OFF
Choose one of the Normal Tours or Relay output as the
dome's alarm action.
RESET ACTION
Function:
Set a Reset action that occurs once the alarm has been
acknowledged.
Options: NONE -
Indicates a no-action command that disables
the automatic preset call (default).
PRESET 001 ~ PRESET 032 -
Select one of the 32
presets for automatic call up.
AUTOPAN/AUTO TOUR 001~ 004:
Choose one of
the autopan/Auto Tour as the dome's alarm reset action.
NORMAL TOUR 001~ 004: AUX ON/OFF
Choose one of the Normal Tours or Relay output as the
dome's reset alarm action.
ACK MODE
Function:
Sets the Acknowlegement mode and time following an
alarm activation.
Options:
Manual/Momentary/1 – 89 seconds.
Important Note: As this dome currently only supports
Simplex telemetry, Alarm Acknowledgement mode must
be set to Auto 1 – 89 Seconds.
4.6.3 SECTOR SET
The "SECTOR SET" feature allows the entire surveillance site to
be divided into a maximum of 16 sections (sectors). Each section
can be labeled with a unique sector number and a descriptive title,
which will display on the screen when the camera navigates
through it.
Illustrated below is a waiting hall at an airport passenger terminal
that is under the surveillance of a dome and has been partitioned
into 8 sections using the "
sector
" feature.
Gate 9
Gate 10
Escalator up
Escalator down
Information
desk
Lounge
Restaurant
Telephone
Area 1
Area 2
Area 3
Area 4
Area 5
Area 6
Area 7
Area 8
Super
Dome
As the example shows, partitioned
sector
s together usually
constitute a contiguous 360-degree view around the domes, with
the ending point of one
sector
as the starting point for the next.
Note that the ending point of the last
sector
cannot surpass the
starting point of the first.
Sector
s may be assigned different sizes to meet the requirements
of a particular installation. In the example shown above, the two