background image

 

 

 

 

14 

 

TITLE SET 

Function: 

Set title for the  selected 

AUTOPAN  (up to  16 

characters). 
Display  can be set to display or not. If set to  ON, the title  will 
show on display when scanning. 

Options: 

A  total of 62 characters, including English letters in 
upper and lower cases, as well as numbers from 0 to 9, 
are available for editing the title.     

Steps

 

1.

 

Move the cursor to the first character of title. 

2.

 

Move the operation  hand up and down to select character or 
blank. 

3.

 

Move the cursor to the next character. 

4.

 

Repeat steps 2 and 3 to complete the title. 

 

TITLE CLEAR 
Function:

 Clear some or all of the autopan titles. 

Options:

 

001 ~ 004

 - Clear the selected title. 

        

ALL

 - Clear all of the titles. 

 
AUTOPAN CLEAR 
Function:

 Clear some or all of the autopans. 

Options:

 

001 ~ 004

 – Clear the selected autopan. 

        

ALL

 – Clear all of the autopans. 

 

4.5.3 AUTO TOUR 

An Auto Tour is the patrol route of the dome and can be called up 
by  keypad.  The  dome  can store  horizontal, vertical and zoom 
operation and repeat this operation accurately when applied. This 
auto tour identity can be used to define the normal route.   

 

 

TITLE DISP 
Function: 

Enable/disable title display. 

 
AUTO TOUR NO.   

Functions: 

Select auto tour to be set with title.   

 

TITLE SET 

Functions: 

Define name for auto tour (up to 16 characters). 

Options: 

A  total of 62 characters, including English letters in 
upper and lower cases, as well as numbers from 0 to 9, 
are available for editing the title.     

 

Edit Auto Tour title: 

1.

 

Move the cursor to the first character of title. 

2.

 

Move the operation hand to select character or blank. 

3.

 

Move the cursor to the next character. 

4.

 

Repeat steps 2 and 3 to complete the title. 

 

TITLE CLEAR 

Function: 

Clear some or all of the titles. 

Options: 

001 ~ 004

 – Clear the selected pattern title. 

         

ALL

 – Clear all of the pattern titles. 

 

AUTO TOUR CLEAR 

Function:

 Clear some or all of the auto tours. 

Options: 

001 ~ 004

 – Clear the selected 

auto tour

ALL 

– Clear all the 

auto tour

s. 

 

4.5.4 HOME RETURN 

After receiving no command for a certain  period of time, the 
domes can automatically return to a position that has been 
previously defined ("home position"). This feature ensures that the 
domes view a key area when not controlled by a user. It can be set 
up in the HOME RETURN SET menu. 

HOME RETURN SET

= = = = = = = = = = = = = =

  HOME POSITION: NONE
  RETURN TIME:  

000S

  RETURN

  EXIT

  POWER OFF SAVE:  OFF

 

 

HOME POSITION

 

Function:

  The home position parameters. 

Options:

 

NONE -

 

Disable the home position feature. 

 

PRESET 001 ~ PRESET 032:

  Choose  one of the 32 

presets as the dome's home position. 

 

AUTOPAN/PATTERN  001 ~ 004: 

Choose  one  of the 

autopan or patterns as the dome's home position. 

Note:

  Before selecting a preset as the home position, make sure 

that it has been properly set. 

 

RETURN TIME

 

Function:

  Determine how long the dome can be inactive before it 

returns to its home position. 

Options:

  000s (default), 005s, 010s, 020s, 040s 060s, 5 mins,   

10 mins, 20 mins, 40 mins, 1 hour. 

Note:

  The  option of “000s” means that there is no  Home Return 

action. 
 

POWER OFF SAVE 
Function:

 Enable/disable power off save function. 

Options:    OFF 

– Disable the power off save function (default).

 

 

 

ON 

– Enable the power off save function. 

Summary of Contents for Surveyor MKII

Page 1: ...in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Document Number 8009 8283 30 01 Product specifications subject to ch...

Page 2: ...l other trademarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII Analog PTZ Domes comply with the FCC rules Operation is subject to the following two conditions...

Page 3: ...nded by manufacturer Position power source and related wires to assure they will be kept away from ground and access way Refer all service matters to qualified personnel Save product packaging to ensu...

Page 4: ...e The Surveyor MKII analog domes provide video transmission over coaxial cable They are compatible with the leading controllers in the market and can be controlled directly by Vicon keypads controller...

Page 5: ...surveillance area automatically A description title for the autopan can be programmed and stored in the domes The domes after receiving no command for a programmed period of time will automatically re...

Page 6: ...rations Instructions Camera Call up NOTE The dome cameras must be called up put under the control of via the keypad before operation or programming To call up a camera enter the camera ID number and p...

Page 7: ...Tour is a series of defined steps the dome can take and can be called up by a keypad The dome can save horizontal vertical and zoom operations and it can repeat these operations accurately when appli...

Page 8: ...r keys 9 and 8 and then press PRESET button to start programming autopan PRESET 9 Press Press the number key 1 PRESET Press the number key Press 4 The following overlay messages will be displayed Pres...

Page 9: ...ore than 5 minutes it will exit automatically 4 2 MAIN MENU 1 SYS INFO SET 1 1 SYSTEM SET Display the current S N number Display the camera ID number Display the broad ID Display the control protocol...

Page 10: ...to tour number Set auto tour title Clear title Clear auto tour 3 4 HOME RETURN SET Set home return position Home return time Power off save 3 5 NORM TOUR SET Tour number Action and Time The dome can b...

Page 11: ...COMM MODE LENS TYPE VERSION V1 00 05 BAUD RATE 485 RETURN 255 EXIT P236B CURRENT S N Function Display the current serial number of the domes MODEL Function Display the model name CAM ADDR Function Dis...

Page 12: ...OFF HUMIDITY Function Turn the Humidity title ON OFF PRESSURE Function Turn the Pressure display ON OFF Only available on pressurized model dome PRESSURE ALARM Function Enable Disable the Pressure Lo...

Page 13: ...WHITE BALANCE SET EXPOSURE SET SPECIAL FUNCTION EXIT RETURN 4 4 1 ZOOM SET DIGITAL ZOOM Function Enable disable digital zoom Options OFF Disable digital zoom function default ON Enable digital zoom fu...

Page 14: ...tor when changing the R gain value The greater the number is the more reddish the picture becomes WB B Function Allow manual adjustment of B gain value for customer white balance Options 000 255 The c...

Page 15: ...black and white show a striking contrast When the target is exposure is correct indoor or outdoor the image can be presented clearly The WDR function can be only be enabled when the Prior Mode of Exp...

Page 16: ...the title is complete TITLE CLEAR Function Clear some or all of the preset titles Options 001 255 Clear the selected preset title ALL Clear all of the preset titles Note When the set value surpasses 2...

Page 17: ...the cursor to the first character of title 2 Move the operation hand to select character or blank 3 Move the cursor to the next character 4 Repeat steps 2 and 3 to complete the title TITLE CLEAR Func...

Page 18: ...ote PRESET 80 85 PRESET keypad switch is set at OPERATE position can call up tour 1 6 The ACT will be determined by the TIME in the TOUR If the tour is set with time only no act the dome will perform...

Page 19: ...K NO Function Selected the area to be masked Options 001 016 options MASK STATUS Function Enable disable the privacy mask function of the area Options OFF Display the area default ON Mask the area Not...

Page 20: ...occurs once the alarm has been acknowledged Options NONE Indicates a no action command that disables the automatic preset call default PRESET 001 PRESET 032 Select one of the 32 presets for automatic...

Page 21: ...entry of the title item 2 Deflect the joystick downward or upward to select a suitable character or a space 3 Move the cursor to the next entry 4 Repeat steps 2 and 3 until the entire title has been e...

Page 22: ...splay the lens direction and angle in real time When the COMPASS DISP is set to ON the COMPASS SET menu is shown as below SET THE NORTH Operation Set COMPASS DISP to ON deflect cursor to SET THE NORTH...

Page 23: ...ART and END H POSI and the START and END V POSI values by moving the joystick left or right Be sure to avoid crossing over the values THRESHOLD Function Sets the amount of activity required to generat...

Page 24: ...above Follow the instructions shown on the screen during operation For Preset Autopan Auto Tour setup and calling up shortcut operations for special functions refer to the table that follows This show...

Page 25: ...es Zoom Selected Area Yes PELCO D Protocols VICON PELCO P D auto detect Number of Address 1 254 Baud Rate 2400 4800 9600 19200bps Manual Speed Pan 400 s Tilt 150 s Preset Speed 400 s maximum Pan Trave...

Page 26: ...nsitivity Color mode IR Cut On 1 4 lux NTSC 1 60s PAL 1 50s 0 1 lux NTSC 1 4s PAL 1 3s B W Mode IR Cut Off 0 01 lux NTSC 1 4s PAL 1 3s Horizontal 550TVL S N Ratio 50dB Video Output 1 0 0 2Vp p Backlig...

Page 27: ...rolled after successful initiation New camera ID has not been activated Recycle the power Protocol or Baud rate Dip switch settings are incorrectly chosen Proper set the Protocol and Baud rate Wrong c...

Page 28: ...nal by the original end user The sole remedy under this Warranty is that defective equipment be repaired or at the Company s option replaced at Company repair centers provided the equipment has been a...

Page 29: ...Vicon product whether resulting from breach of warranty or any other legal theory Notwithstanding the foregoing Vicon total liability for all claims under this warranty shall not exceed the price pai...

Page 30: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Reviews: