4.5.5 NORM TOUR SET
NORM TOUR SET
= = = = = = = = = = = = = =
TOUR NO : 001
1 000
000
3 000
000
5 000
000
7 000
000
9 000
000
11 000
000
13 000
000
000
000
RETURN
EXIT
ACT TIME
ACT TIME
2
14
12
10
8
4
6
000
000
000
000
000
000
000
000
000
000
000
000
Function:
Link the actions in a tour.
Options:
The dome can be set with up to 6 tours, with each tour
including 14 actions (displayed in two columns); the actions can
be presets, patterns, autopans, and each action time can be defined
independently.
TOUR NO.:
001 ~ 006
ACT:
Move the joystick up and down or left and right to select the
desired action (preset 1
~
32, pattern 1
~
4, autopan 1
~
4).
Note:
Make sure the action is set correctly before using it in the
tour set.
TIME:
000 ~ 060 sec.
Note:
PRESET 80-85 PRESET (keypad switch is set at
OPERATE position) can call up tour 1~6. The ACT will be
determined by the TIME in the TOUR. If the tour is set with time
only, no act, the dome will perform the tour by pausing at the set
position for the set time without action.
4.5.6 PTZ TIME OUT
TIME OUT VALUE:
Function:
Set a value after which an action will be carried out
following a loss of telemetry control. This can prevent a dome
from spinning uncontrollably.
Options:
1-255 Seconds
ACTION:
Options:
Preset 1-32, STOP
4.5.7
SCHEDULER
EVENT NUM
Function:
Select Event number.
Options:
1-64
ACTION
Function:
Select Action.
Options:
Presets 1- 32, AutoTour 1-4, AutoPan 1-4
Aux ON/OFF, Alarm 1-4 ON/OFF, Tour 1-6, None.
TIME OF DAY
Function:
Set the time of day that Scheduler starts.
SCHEDULE
Function:
Set the frequency of the schedule.
Options:
Once, Weekly
DAY OF WEEK
Function:
Set the day that Scheduler starts.
Options:
Daily, Sunday - Monday