Outdoor Pendant Model
The Outdoor Pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.0-
inch vertical pipe in the same manner as the indoor version. The outdoor version includes a sunshield, heater
and weather protection.
The mount is installed with all the cables run through it and the 1.0-inch NPT pipe is prepared with sealant for
the housing and the Surveyor2000 installation. The cables are routed through the housing and the housing is
screwed tightly to the pipe. Then the Surveyor2000 is hung from the housing safety cord while it is wired and
configured. The Surveyor2000 is then carefully snapped into the housing. The entire Surveyor2000 is
supported by the mount. The outdoor lower dome is then anchored with its safety cord, snapped on and
screwed tight to the Surveyor2000. See Figure 16. Detailed installation instructions will follow.
The accessory kit containing the RJ-45 to RJ-45 8 foot (2.4 m) cable and RJ-45 termination box can be used
for wiring the 4 alarms or the relay in this installation. Since the supplied cable is limited to 8 feet (2.4 m), the
ermination box must be mounted within the immediate area of the Surveyor2000.
t
The mount must provide a support of suitable strength for the sunshield, housing and the Surveyor2000
1.
ount or
prepare the vertical 1.0-inch NPT pipe.
2.
0-inch NPT
pipe, 16-inches (406 mm) in length.
3.
unt
and feed the cables through its top opening.
4.
s of the pipe. Follow instructions on the
stick.
NOTE:
Failure to thoroughly coat the first 2-3
weight of 6.5 lb (2.9 kg).
Outdoor Pendant Mount Model
Figure 16
Install the mount in accordance with the
installation manual included with the m
Feed all necessary cables through the back of
the mount and out the end of the 1.
Lift the sunshield and housing up to the mo
Apply the provided sealant to the first 2-3
thread
threads will result in moisture entering the
housing and eventual failure of the
Surveyor2000.
Place the housing onto the 1.0-inch pipe and
screw clockwise, looking up at the housing.
When it beco
5.
mes snug, turn it an additional
quarter-turn.
6. Verify that each cable drops from the pipe
opening at least 16-inches (406 mm) in length.
7.
the housing’s safety cord to the Surveyor2000’s latch.
Allow the Surveyor2000 to hang from the housing.
Lift the Surveyor2000 up to the housing and attach
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Installation
•
23
Summary of Contents for SURVEYOR 2000 7003-00
Page 2: ......
Page 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Page 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Page 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Page 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Page 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Page 63: ......