Summary of Contents for SURVEYOR 2000 7003-00

Page 1: ...situations and must not be used for this purpose Copyright 2003 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trade...

Page 2: ......

Page 3: ...sing Assembly 5 Installation 7 Quick Installation In Ceiling Model Ceiling Access 7 Quick Installation In Ceiling Model No Ceiling Access 8 Quick Installation Indoor Pendant 9 Quick Installation Outdo...

Page 4: ...Line Jumpers JP1 JP2 JP3 for RS 485 Protocol Operation 41 Uninstalling the Surveyor2000 43 For an In Ceiling Installation 43 For a Pendant Installation 43 Operation 45 Initial Power Up 45 Verifying Pr...

Page 5: ...odels Model Number t t m er service Surv Environmen yor2000 M Camera Mount Produc Code Cable Type Type Format Type Optical Zoom Total Zoo Lower Dome Type S2000 CC22 EX 8211 00 Indoor Coax Color NTSC C...

Page 6: ...Code escription Model Num Produ D S2000 UWM 7032 Wall mount indoor outdoor S2000 UCM 7033 Ceiling mount indoor outdoor S2000 1PC UPM or 7428 Parapet mount outdo S2000 URM 7035 Roof mount outdoor S200...

Page 7: ...lower dome care Refer to the subsequent sections of Installation Wiring Configuration and Operation for detailed descriptions of any method For Novice Installers Complete the remainder of this section...

Page 8: ...lief fitting is used as an alternate means of providing support for cables on the In Ceiling Mount model when flexible conduit pipe is not used Refer to the In Ceiling Mount model sub section of the I...

Page 9: ...e top of the Camera Drive There are variations in camera type for format magnification and day night usage Shroud The Shroud is a 5 4 in 137 mm textured black ABS plastic shell It has a 1 2 in 30 5 mm...

Page 10: ...Figure 3 Surveyor2000 Outdoor Pendant Figure 2 Surveyor2000 Indoor Pendant 6 Introduction XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 11: ...n the specific unit purchased In Ceiling Indoor or Outdoor Pendant Quick Installation In Ceiling Model Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N XX031 01 Rev 8...

Page 12: ...Quick Installation In Ceiling Model No Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 8 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 13: ...Quick Installation Indoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N XX031 01 Rev 803 Surveyor2000 Camera Dome System Installation 9...

Page 14: ...Quick Installation Outdoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 10 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 15: ...ial occupying the space between the lower ceiling and upper building frame There are 2 methods of installation The first method is for ceilings with no access to the space above as in a typical hard m...

Page 16: ...ing the nut and sliding it out Install the supplied strain relief fitting in its place and re attach the top cover Hold the enclosure near the hole in the ceiling and route approximately 9 inches 229...

Page 17: ...7 rminal blocks TB1 and TB3 into the Communication Power Supply Board at the proper block frames 8 for coax installations or connect twisted pair video wires to screw terminal TB4 for UTP installatio...

Page 18: ...with their mating standoffs and insert the camera drive into the enclosure When seated tighten the 3 captive screws 12 Lift the lower dome up to the Surveyor2000 and line up the 2 molded tabs on the...

Page 19: ...ination box in this situation Detailed installation instructions will follow The ceiling material must provide a surface of suitable strength for the Surveyor2000 weight of 4 5 lb 2 0 kg on the area o...

Page 20: ...e le or communication relay cable with an RJ 45 male connector if connectors J2 and J3 will be used Strip approximately 1 inch 25 mm of insulation off all wires to be terminated in Make all connectio...

Page 21: ...S 422 mode will be used 1 Set switches 1 8 on DIP switch 1 S1 to Surveyor2000 s address as specified in Table 3 All addresses between 0 and 255 are valid address 0 is the same as camera number 256 2 S...

Page 22: ...IP switch 2 S2 to either position as it does not affect Vicoax protocol operation NOTE DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning 10 Lift the lower dome up to the Surveyor...

Page 23: ...the caddy rail clips to the existing frame Remove adjacent tiles to access the clips 3 Adjust the position of the caddy rail clips along the frame to obtain the best X position 4 Slide the assembly al...

Page 24: ...and the Surveyor2000 weight of 5 7 lb 2 6 kg 1 Install the mount in accordance with the installation manual included with the mount or prepare the vertical 1 0 inch NPT pipe 2 Feed all necessary cable...

Page 25: ...nication Power Supply Board s mating BNC connector at location J1 10 for coax installations or connect twisted pair video wires to screw terminal TB4 for UTP installations Plug in all RJ 45 cable conn...

Page 26: ...ooking up until the arrow on the Installation Label is aligned with the arrow on the inside of the housing as shown in Figures 14c and 14d 17 Push the Surveyor2000 straight up into the housing as show...

Page 27: ...m the ermination box must be mounted within the immediate area of the Surveyor2000 t The mount must provide a support of suitable strength for the sunshield housing and the Surveyor2000 1 ount or prep...

Page 28: ...relay cable with an RJ 45 male connector if connectors J2 or J3 will be used WARNING If Vicoax mode is being used DO NOT wire TB3 or J3 with control signals as this will cause the camera dome program...

Page 29: ...ockwise looking up until the arrow on the 8 Push the Surveyor2000 straight up into the housing as shown in Figures 17d and 9 Lift the lower dome up to the Surveyor2000 and press in its safety cord plu...

Page 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 31: ...nd the control system that requires two individually shielded twisted pair cables implex m the control system to the ESPONSE OUT RO A signal from the Surveyor2000 to the CPU in response to a COMMAND I...

Page 32: ...ORMALLY OPEN NO ACTIVE LOW CLOSED Figure 20 Typical Relay Circuit The active state can be programmed through the Surveyor2000 menu system These signals are connected to RJ 45 Connector J3 Alarm signal...

Page 33: ...NOTE If conduit pipe is not used the supplied strain relief fitting must be installed in place of the one installed to provide sufficient cable strain relief Figure 21 In Ceiling Mount Model Cable Ins...

Page 34: ...cable stallation details 1 cut each cable The approximate total length of these cables should be 13 to 16 inches 330 to 406 mm 2 e Relay signals exist only in J3 Therefore remove TB3 only if the cont...

Page 35: ...those connections Figure 22 Indoor Pendant Mount Cable Installation 8 Plug in all RJ 45 cable connectors to their corresponding mating connectors J1 and J3 WARNING Failure to insert the RJ 45 connecto...

Page 36: ...le Figure 24 Feed the control cable into one of the sides and connect each wire to the appropriate screws Figure 26 is shown wired for typical Surveyor2000 duplex operation with no relay NOTE Upon ini...

Page 37: ...from the control unit CPU or previous Surveyor2000 into one of the sides of the termination box and connect each wire to the appropriate screws 5 Feed the remaining control cable from the next sequent...

Page 38: ...connection from open wires to open wires After the cable is passed through the cable fitting ceiling mounted Surveyor2000 only connect it to termination box s terminals When the cover of the terminat...

Page 39: ...2 5 ALARM3 Alarm input 3 J2 6 VSSA Ground J2 7 ALARM4 Alarm input 4 J2 8 VSSA Ground TERMINAL BLOCK COMM TB3 TB3 1 VSSA Ground TB3 2 RO Response out TB3 3 CI Command in TB3 4 RO Response out TB3 5 CI...

Page 40: ...GUI Call Technical Support at 1 800 34 VICON 1 800 348 4266 Standalone Configuration When one PC is being used with one dome the PC must be connected to the Surveyor2000 by means of Vicon s RS 232 RS...

Page 41: ...udes the RS 232 RS 422 Interface Converter is used part number 1251 3555 01 In this configuration connect the converter end of the assembly to the COM 1 SERIAL port of the computer and the other end t...

Page 42: ...System After the physical connections are made insert the S2000 PCSW disk and select the appropriate program Flash Upgrade Utility or PC Direct Control Software 38 Wiring XX031 01 Rev 803 Surveyor2000...

Page 43: ...LEX OFF Position 4 is the protocol mode setting RS 485 ON or RS 422 OFF Each switch is numbered from 1 to 8 and marked to indicate the ON position Surveyor2000 will automatically detect the system s b...

Page 44: ...X X X 42 X X X 128 X 214 X X X X X 43 X X X X 129 X X 215 X X X X X X 44 X X X 130 X X 216 X X X X 45 X X X X 131 X X X 217 X X X X X 46 X X X X 132 X X 218 X X X X X 47 X X X X X 133 X X X 219 X X X...

Page 45: ...or2000 to access the jumper sockets Refer to the Uninstalling the Surveyor2000 section of this manual 2 Install all 3 jumpers by pushing them over the 2 pins for each socket on a Surveyor2000 which is...

Page 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 47: ...the ceiling It will hang from the safety cord Refer to Figure 31 3 If it is necessary to completely remove the camera drive disconnect the safety cord clip and all cables For a Pendant Installation 1...

Page 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 49: ...the AC power on to the Surveyor2000 The monitor will display the power up test screen Figure 33 for the duration of its initial testing This test displays the status of the functions pan tilt zoom fo...

Page 50: ...isplays the Surveyor2000 Main Menu as shown in Figure 35 5 Set up the Surveyor2000 as desired using the remote keypad Proper operation has been verified Use of the Auto Baud Detect Feature Entering Pr...

Page 51: ...yor2000 is not communicating with the control device Verify that the Surveyor2000 address is selected on the control device Sometimes moving the joystick can begin communication If communication canno...

Page 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 53: ...inside to the outer edge Use a new wick for each 2 passes over the dome Clean the lower dome s exterior with any soft nonabrasive cleaning cloth and a cleaning agen 5 t suitable for acrylic plastic Ei...

Page 54: ...5 mAh It will be necessary to replace the battery when upon power up the time is reset and the previous programming configuration is reset to factory defaults The battery is accessible on the camera d...

Page 55: ...ted Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit icon employee who issued...

Page 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Page 57: ...deo quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approve...

Page 58: ...Belden are used Materials and construction must follow the guidelines above ecommended Individually Shielded Twisted Pair Cable Types P receiver is required Vicon offers three ceivers to provide vide...

Page 59: ...tion Outdoor 48 0 W nominal heater included Outdoor 2 7 btu min 0 6 cal min Note Indoor 28 8 W nominal Heat Equivalent Indoor 1 6 btu min 0 4 cal min These figures represent the conversion of 100 of t...

Page 60: ...to end Preset Capabilities 79 individual programmable preset positions 8 tours available with 32 programmable events per tour Events may be preset positions alarm alarm or preset dwell times relay fu...

Page 61: ...re Range RS 422 or RS 485 protocol selectable via DIP switch S2 Communication is simplex or half duplex operation at superimposed data on composite video signal automatically detec C On screen menu dr...

Page 62: ...1 Indoor Coax Mono CCIR Pendant 22x 264x Not Included S2000 CW22 EX 8215 00 Outdoor Coax Color NTSC Pendant 22x 264x Clear S2K CW22NVT 8287 00 Outdoor UTP Color NTSC Pendant 22x 264x Clear S2000 CW22C...