50
DEFECT
REASON
ELIMINATION
8.
To the boiler there is connected
the stack HWS heater according
to the recommended diagram and
the HWS isn’t heated preferentially
Faulty connection of Honeywell V
4044F three-way valve
Check the valve connection – see
fig.no. 21
Faulty three-way valve
Exchange the valve
9.
To the boiler there is connected
the stack HWS heater according
to the recommended diagram and
HWS isn’t heated to the required
temperature or it does not show
the required temperature
Wrong temperature setting on the
thermostats
* Change
the
setting
see
chap.
no. 11
Faulty
heater
thermometer
or
thermostat, or the boiler thermostat
Exchange the faulty safety or regulation
element
10. The combustion products return
flow fuse blocked
Clogged chimney
Clean the chimney
Clogged the smoke-flue output end
(at the boilers equipped with
combustion products ventilator)
Check,
unblock
the
combustion
products return flow fuse
A strong wind inducing the counter-
pressure
* unblock the combustion products return
flow fuse
by using the "RESET" button in the
network module.
17. Guarantee and liability for defects
VIADRUS a.s. provides the guarantee:
–
For boilers 24 months after the boiler putting into operation, but maximum 30 months after the date it
was dispatched from the manufacturing factory.
–
For boiler drum 10 years after the date its dispatch from the manufacturing factory.
The manufacturer requires for the guarantee applicability:
–
In sense of Act no. 222/94 Coll. „On business conditions and government administration
execution in certified branches and on State electricity inspection“ and
Č
SN 38 6405,
EN 1775 to inspect the gas boiler regularly once a year. The inspections can only be done by an
authorized organization (contractual service), accredited by VIADRUS a.s.
–
To document all records of carried out guarantee and after-guarantee repairs and regular annual
inspections in the annex to the guarantee certificate enclosed to this manual.
Every defect must be announced immediately after having been found out and always in writing on
the basis of an telephonic agreement.
If the above instructions are not observed then the guarantees provided by manufacturer will not be
acknowledged
The guarantee does not apply to the:
-
faults caused by improper assembly and improper attendance of the product and faults caused
by improper maintenance see chap. 14;
-
faults and damage caused by failure to observe water quality in heating system see chap. no. 9.1
and 10.2 or by using the anti-freeze mixture;
-
faults caused by failure to observe instructions stated in this manual;
-
products damaged during transport or by other mechanical damage;
-
defects caused by an inconvenient way of storing.
The manufacturer reserves the right to make changes within the product innovations that needn’t be
included in this manual.
The manufacturer isn’t responsible for damages caused by using the product in a discordance with
conditions stated in this operation manual.
The manufacturer provides the product guarantee for a period and under the conditions that are
quoted in guarantee certificate. The guarantee certificate is a part of delivery and its validity is
conditioned by all data full, legible and truly filling in.
Summary of Contents for GARDE G 42 ECO
Page 52: ...52...
Page 56: ...56...
Page 58: ...58...
Page 59: ...59...
Page 60: ...60 Date of revision 16 2013 GB...