46
6. If there occurs the boiler failure state, the failure signalisation in automatics lights up. The most
common reasons for failures and the possibilities to eliminate them are shown in chapter no.16. The user
can only eliminate the failures signed with symbol „*“. In case of electricity outage the burner is put out of
operation and after the voltage recovery in the electricity network the burner is restarted automatically.
The failure is unblocked by means of “unblocking” button in the network module.
7. The safety thermostat unblocking. If the boiler has been switched off by the safety thermostat then the
“overheating” signal lamp lights up on boiler control panel. The thermostat can be unblocked by user in
the network module (TB). Safety thermostat switching off can be caused by several reasons, see chapter
no. 16.
8. Combustion products return flow fuse unblocking. If the boiler has been switched of by the fuse then
the “overheating” signal lamp lights up in network module. The TS fuse can be unblocked by user in the
network module.
1. electric panel
2. blind flange big
3. customs panel
4. fuse box
5. boiler thermostat
6. blind flange
7. reset push-button
8. exceeded temperature signalling
9. thermomanometer
10. blind flange with thermomanometer
11. fuse 2,5A
12. main switch
13. unblocking of combustion products return
flow fuse
Fig.no. 28b)
Standard control panel of VIADRUS GARDE G 42 and VIADRSU G 42ECO boilers with
Honeywell automatics for NG and 1°a propane
Summary of Contents for GARDE G 42 ECO