23
Heating circuit 1
Parameter
Function
Factory settings
Min.
Max.
Units
710
Comfort temperature
20
Line 712
Line 716
°C
712
Setback temperature
16
Line 714
Line 710
°C
714
Anti-frost temperature
10
4
Line 712
°C
720
Heating curve slope
1.5
0.10
4.00
-
730
Summer / winter automatic
18
---/8
30
°C
742
Req. T Run-up Room Thermostat
65
Line 740
Line 741
°C
855
Cur. req. drying temp.
---
0
90
°C
856
Current drying day
----
0
32
-
Comfortable temperature
required room temperature that will be maintained at the heating phase.
Setback temperature
required room temperature that will be maintained at the setback phase.
Anti-frost temperature
setting of the required anti-frost room temperature.
Heating curve slope
the value shows the heat curve setting, see Fig. No. 18
Summer/winter automatic
temperature limit for switching between summer and winter mode.
Req. T Run-up Room Thermostat
the temperature to which the boiler will heat when the outside sensor is not
used.
Current req. drying temp
setting of the temperature for drying of the floor heating.
Current drying day
setting of the drying day for the floor heating.
Hot water
Parameter
Function
Factory settings
Min.
Max.
Units
1610
Rated temperature
55
8
80
°C
Nominal temperature setting the required comfortable hot water temperature.
Set heating curve uses the required room temperature of 20 °C. If the required/room temperature changes, the
heating curve changes as well. The heating curve shows the required temperature to the heating circuit depending
on the corrected outside temperature.
When using the room unit QAA74, QAA75 etc, in addition, the heating curve is corrected by the parameters Set
room temperature and Room influence.
Summary of Contents for CLAUDIUS K 2 Series
Page 1: ...VIADRUS CLAUDIUS K 2 Manual for boiler operation and installation GB_2016_35 GB_2016_43...
Page 30: ...30...
Page 31: ...31...